Check whether the central unit can be started via the low voltage connector (figure 1: 8) of the 
central unit by closing the start circuit with a piece of metal wire.

In  case  of  suction  hoses  that  are  equipped  with  a  handle  start  mechanism,  check  that  the  start 
circuit of the hose is intact. If the central unit can be started by connecting the contact pins of a 
wall inlet with a piece of metal wire, for example, but not with the control switch on the suction 
hose handle, the fault is either in the hose or in the switch. 

If  the  central  unit  can  be  started  via  the  low  voltage  connector  but  not  by  opening  a  wall  inlet, 

check that there are no breaks in the wires.

Check  whether  the  overheat  protector  of  the  electric  motor  has  tripped  (see  section  Safety 

Devices).

Check whether the overheat protector of the turbine has tripped (see section Safety Devices).

Check  whether  the  overload  protector  of  the  electric  motor  has  tripped.  If  this  is  the  case,  the 

start relay of the central unit will make a clicking sound but the motor will not start; contact an 
authorised Allaway service dealer.

5.2 WHAT TO DO IF SUCTION POWER HAS DROPPED

Check that all other wall inlets are closed and that they do not leak.

Check that there are no objects inside the wall inlet that could obstruct flow.

Check that the suction hose is intact and that no objects that could obstruct flow are lodged in 
it.

Check that the dust canister is correctly in place and that the sealing materials of the dust canister 
are clean and intact.

Check that the dust canister is not full or that the dust bag does not require replacing.

Check that the filter is in good condition.

Check that the pipe system is airtight.

5.3 WHAT TO DO IF THE SUCTION HOSE IS DAMAGED

Cut  the  damaged  section  out  and  reconnect  the  hose  using  an  extension  coupling  muff  (accessory). 
If the hose breaks near the hose coupling muff or the handle, detach the muff or handle, cut out the 
damaged section and twist the hose coupling muff or handle back onto the hose. The components of 
the hose have a left-handed thread.

In suction hoses equipped with a handle start mechanism, the start circuit wires are built into the hose. 
The  hose  cannot  be  shortened  or  extended.  In  case  of  damage  to  the  hose,  contact  an  authorised 
Allaway service dealer.

Summary of Contents for C 30 PREMIUM

Page 1: ...INSTRUCTIONS FOR USE AND MAINTENANCE CENTRALVACUUM CLEANERS C 30 PREMIUM C 40 PREMIUM C 40 premium LCD...

Page 2: ...Start 6 5 2 What to Do if Suction Power Has Dropped 7 5 3 What to Do if the Suction Hose Is Damaged 7 5 4 What to Do if the Pipe System or the Exhaust Pipe Is Blocked 8 5 5 Details Required for Maint...

Page 3: ...first time please check that the dust canister is empty and that the filter is in place n If the central unit is used for vacuuming anything other than normal dust a suitable Allaway pre separator mus...

Page 4: ...at a muffler accessory be fitted onto the exhaust pipe The muffler should be positioned as close to the end of the exhaust pipe as possible for maximum power Mufflers must not be installed on the suct...

Page 5: ...wer cord 5 into the socket We recommend that the filter is replaced at least every 3 years If a dust bag is used only replace the filter when necessary 2 3 Cleaning Accessories Tell children how to us...

Page 6: ...min Find out why the overheat protector has tripped and eliminate the cause e g full dust canister blocked filter blockage in the pipe system wall inlet exhaust pipe cleaning accessories or the blow o...

Page 7: ...tart contact an authorised Allaway service dealer 5 2 Whatto Do if Suction Power Has Dropped n Check that all other wall inlets are closed and that they do not leak n Check that there are no objects i...

Page 8: ...ir in between and to stop it from overheating Repeat the process after approximately one minute n If the blockage cannot be dislodged through suction and you are able to pinpoint its location it is wo...

Page 9: ...shards of glass may damage the pipe system The system must not be used for vacuuming liquids or substances other than normal dust unless a suitable Allaway pre separator is used 7 2 Dust Bag Installa...

Page 10: ...by declares that Central Vacuum Cleaners Type TE 1650 TE 1750 have been manufactured in accordance with the relevant harmonised standards and fulfils the essential requirements of the LowVoltage Direc...

Page 11: ...OG Type ____________ No ____________ First Used on date ____________ Dust Canister Emptied or Dust Bag Replaced Filter Cleaned Filter Replaced Dust Canister Emptied or Dust Bag Replaced Filter Cleaned...

Page 12: ...hone 39 0438 498910 erretiesse erretiesse it www erretiesse it Latvia Aero Clean Studio Sia Atlasa 7a Riga Riga LV 1026 phone 371 67 88 69 24 info aeroclean lv www allaway lv Poland WPH Wirexim Sp z o...

Reviews: