Installation Instructions 

 

BEFORE USE: 

 

Remove the exterior and interior packaging. 

 

Before connecting the unit to the power source, let it stand upright for approximately 8 hours. This will reduce 

the possibility of a malfunction in the cooling system from handling during transportation. 

 

Clean the interior surface with lukewarm water using a soft cloth.  

 

This appliance is designed for freestanding use.  Ensure that there is 2” of air space on both sides, and 3” in back. 

 

Place the unit on a flat, solid floor that is strong enough to support it when it is fully loaded. To level the 

appliance, adjust the front leveling leg at the bottom of the unit.  

 

When moving your wine cellar, please do not incline it more than 45 degrees.  

 

Locate the appliance away from direct sunlight and sources of heat (stove, heater, radiator, etc.). Direct sunlight 

may affect the acrylic coating and heat sources may increase electrical consumption. Extreme cold ambient 

temperatures may also cause the unit to perform improperly. The optimal ambient temperature range is 65°F - 

80°F  

 

Avoid locating the unit in damp areas.  

 

Plug the wine cellar into an exclusive, properly installed and grounded wall outlet. Do not under any 

circumstances cut or remove the third (ground) prong from the power cord. Any questions concerning power 

and/or electrical grounding should be directed to a certified electrician or authorized products service center. 

 

After plugging the appliance into a wall outlet, allow the unit to cool down for 3 to 4 hours before placing wine 

bottles or beverage cans in the appliance. 

 

Operation Instructions 

 

The wine cellar should be placed in an area where the ambient temperature range is between 55-80 degrees Fahrenheit. 

If the ambient temperature is above or below this range, the performance of the unit may be affected. For example, 

placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate. 

 

 

Your Allavino Wine Cellar includes an operating panel on the front of the unit. The operating panel includes several 

features to operate and control the temperature of the wine refrigerator, including: 

 

Light - Turns the interior light on or off 

Run Indicator Light – Illuminates when the compressor is running 

Upper/Lower Chamber – Adjust and display the temperatures of each zone on individual LED displays 

UP/DOWN Buttons – Adjusts the temperature upwards in 1 degree increments until it reaches maximum temperature, 

and then cycles back to the lowest temperature and begins again 

°C / °F - Toggles the temperature display between Celsius and Fahrenheit 

Power Button - Press to turn on/off the appliance 

 

The unit has a locking door and two keys are provided.  To lock the door, turn the key clockwise and turn it 

counterclockwise to unlock the door.  Keep the keys in a safe place. 

 

If you are going on vacation, you may leave the wine cellar operating during vacations of less than three weeks. If the 

appliance will not be used for several months, you should remove all items and turn off the appliance. Clean and dry the 

interior thoroughly. To prevent mold growth, leave the door open slightly, blocking it open if necessary. 

 

www.allavino.com 

1-888-980-4809 

Summary of Contents for YHWR99-2

Page 1: ...EAD AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Allavino has a policy of continuous improvement on its products and reserves the right to change materials and specifications without notice...

Page 2: ...lation Instructions 5 Operation Instructions 5 Setting Temperature 6 Care and Maintenance 6 Racking Configuration Installation of Door Handle 7 7 Moving Racks Troubleshooting 8 9 Technical Specificati...

Page 3: ...m and Description 1 Control Panel 2 Cabinet Body 3 Storage Shelf 4 Free Ventilation Hole 5 Adjustable Feet 6 Activated Charcoal Filter 7 Door Handle 8 Free Ventilation Base www allavino com 3 1 888 98...

Page 4: ...red Do not kink or pinch the power supply cord of appliance The fuse or circuit breaker size should be 15 amperes It is important for the appliance to be leveled in order to work properly You may need...

Page 5: ...wn for 3 to 4 hours before placing wine bottles or beverage cans in the appliance Operation Instructions The wine cellar should be placed in an area where the ambient temperature range is between 55 8...

Page 6: ...the wine cellar after having been shut off for a long time there will be a few degrees variance between the temperature you select and the one indicated on the LED readout for the first few hours of o...

Page 7: ...ft hand side and push down the lever on the right hand side to remove the shelf from the tracks Installation of Door Handle The Stainless Steel version of this model has optional curved or towel bar h...

Page 8: ...f by sliding guides from walls making sure not to mix up the right and left guides SHELF BRACKET WALL WALL GUIDE Fitting the rear part of the guide Fitting the front part of the guide GUIDE GUIDE GUID...

Page 9: ...ght does not work Not plugged in The circuit breaker tripped or a fuse has blown The light bulb has burned out The light button is OFF Vibrations Check to assure that the wine cellar is on a level sur...

Page 10: ...les Dimensions 64 3 8 H x 23 1 2 W x 21 1 2 D 23 1 8 w handle Weight 167 lbs Voltage Frequency 115v 60 Hz Running Amps 2 3 A Operating Temperature Upper Zone 41 F 54 F Lower Zone 54 F 73 F Ambient Tem...

Page 11: ...equential damages Parts and labor costs for the following will not be considered as warranty o Door springs and or frames o Inner door panels door rails and or door supports o Light bulbs and or plast...

Reviews: