![All-Power APE7210 Operator'S Manual Download Page 9](http://html1.mh-extra.com/html/all-power/ape7210/ape7210_operators-manual_2897974009.webp)
If the engine is stopped in emergency, the engine temperature will rise quickly, thus the engine life
will be shortened.
1. Set the governor lever to the low speed position, then run the engine at zero load for five minutes.
2. Set the governor lever to the “STOP” position. Do no stop the engine with the decompression lever.
3. Set the fuel cock to “OFF” position.
4. Pull the recoil starter handle slowly until you feel resistance.(At this point the decompression just
begins and intake/exhaust valves are both closed and the cylinder can be prevented from rusting.)
5. Turn the starting key to the “CLOSE” position.
PREPARE FOR THE NEXT OPERATION:
1. Fill diesel .
2. Check all the bolts and nuts.
3. Clean the dirt on the surface of the engine body.
7. STOPPING THE ENGINE
15
OPERATING NOTICE
Periodical Check and maintenance are very imortant for maintaning the performance and life of the
engine.
The following is the maintenance intervals and items table. Periodical check and maintenance table.
Intervals
Items
Check all the bolts
and nuts
O
O
O
O
O
O
O
O
Check all the refill
engine oil
Replace engine oil
(First time) (Second time)
O
O
(Clean)
(Clean)
O
(Replace)
O
(Replace)
Clean or replace
engine oil cleaner
Check oil leakage
Replace air cleaner
Clean fuel oil
cleaner
Check nozzle
Check fuel injection
pump
Adjust the clearance of
the intake/exhaust valve
Check the intake/
exhaust valve
Replace the piston
ring
Check the electrolyte
Check it every month, refill the distilled water if necessary.
every day 20 hrs
50 hrs
100 hrs
200 hrs
500 hrs 1000 hrs
8. Periodical Check and Maintenance
16