All Pet Solutions 1000IF Instruction Manual Download Page 2

To ensure your new submersible filtration pump is set up and running correctly, 

and to prevent any accidental damage or injury, please read and follow the below 

instructions carefully before using your product.

 

SAFETY

Important!

 

Disconnect the mains electricity supply before attempting any 

installation / maintenance of any kind. Do not attempt to modify this unit in 
any way and only use the recommended parts for replacement.

·    

 

The unit should never be run dry as this will cause it to overheat and cause 

permanent damage.

·     

All connections must be earthed.

·     

The power cord of this appliance cannot be replaced; if the cord is 

damaged, the appliance should be discarded. Never cut the cord.

·     

Do not connect to any voltage other than that stated.

·     

This filtration pump is suitable for indoor household aquariums only (do not 

use in exterior locations, swimming pools, ponds,  bathrooms etc). Do not 
place in liquids other than water.

·      

Do not use with water above 90F or 30C.

·      

Do not carry or pull the unit by its electrical cable.

·      

Do not use this unit if it has a damaged cord or plug, if it is malfunctioning 

or it is dropped or damaged in any manner

·      

Do not yank cord to pull plug from outlet. Grasp the plug and pull to 

disconnect. Always unplug an appliance from an outlet when not in use.

·      

Do not attempt to modify this unit in any way and only use the 

recommended parts for replacement.

·     

 Before installing, maintaining or handling your equipment, or before placing 

your hands in your aquarium, ensure that the unit is disconnected from the 
electricity supply.

·      

Always unplug any electrical devices when not in use.

Summary of Contents for 1000IF

Page 1: ...SUBMERSIBLE FILTRATION PUMP INSTRUCTION MANUAL 500IF 1000IF 1500IF 2500IF STRONG OXYGENATION EFFECT FOR FRESH SALTWATER TANKS LOW POWER CONSUMPTION QUICK RELEASE FOAM HOLDERS FOR EASY CLEANING...

Page 2: ...ct to any voltage other than that stated This ltration pump is suitable for indoor household aquariums only do not use in exterior locations swimming pools ponds bathrooms etc Do not place in liquids...

Page 3: ...is unit from for further advice If the plug or unit does get wet DON T unplug the cord First disconnect the circuit breaker or fuse that supplies power to the appliance Next unplug and inspect for wat...

Page 4: ...r with a proper rating is essential A cord rated for less amperes or watts than the appliance rating may overheat Please Ensure The power supply must be earthed and fused at 3amps You regularly inspec...

Page 5: ...n Replace Filter Foams Other Media Clean Inspect Replace In general it is recommended to disconnect your ltration pump and clean the impeller and lter sponges monthly The unit will become blocked with...

Page 6: ...e direction of the arrowand remove the front cover part 7 5 Pull up the base buckle pull out in the direction of arrow and pull out the back plate part 15 6 Rotate the impeller cover part 6 in the dir...

Page 7: ...sing part 10 with clear aquarium water NEVER use tap water or soap or detergents when cleaning your unit or rinsing media Make sure no debris is trapped inside Once everything is clean reinsert the lt...

Page 8: ...hould allow 1 gallon of water per 1 inch of sh in your aquarium Follow the instructions in the maintenance section above If you have not yet done so you may also need to carry out more regular water c...

Page 9: ...ank and rinse the gravel until the water runs clear That should resolve the problem if washing the gravel doesn t solve the Dissolved constituents problem the next most likely cause of cloudy water in...

Page 10: ...nges You may also consider reducing the amount of food you give your sh Nitrates As the amount of sh waste rises so do the nitrates Make sure to perform regular water changes check your lter is clean...

Page 11: ...7 FILTER CASE CONNECTION 8 5 SQUARE FOAM FILTER 9 FILTER CASING FILTER BOTTOM 10 11 12 CIRCULAR FILTER SPONGE FILTER CASING FILTER BOTTOM 10 11 12 BACK PLATE IMPELLER SUCTION CUPS 13 14 15 PARTS DIAGR...

Page 12: ...e paid We reserve the right to replace or repair the unit at our discretion Please be aware that perishable parts that are subject to normal wear and tear such as impellers impeller covers and motor s...

Page 13: ...hen completing a replacement or repair Spare parts are available at our o cial website or from your local supplier Before returning your unit under warranty terms check that all setup and maintenance...

Page 14: ......

Page 15: ...www allpondsolutions co uk All Pet Solutions Limited Trading as All Pond Solutions Unit 203 Riverside Way Uxbridge Middlesex England UB8 2YF...

Reviews: