GAS REQUIREMENTS
• The connection between the regulator and the hose must comply with local regulations.
• Never use a gas cylinder with a damaged body, valve, collar or base.
• Rusty or dented gas cylinders can be dangerous and should be checked by a gas supplier.
• Never connect this appliance to an unregulated gas source.
• When the appliance is not in use, turn off the gas supply at the source.
• Always check the connections for leaks when a gas supply is connected. If bubbles form in the soap
solution, do not use the appliance. Never use an open flame to check for leaks.
CONNECTION TO GAS TANK
• It is advisable to use a 13kg Propane gas cylinder. You can use a 6kg compact gas cylinder, Butane (less
efficient) or Propane is preferable if the temperature is close to 0°C.
• Do not connect the gas bottle directly to the appliance without a regulator.
• The flexible tube or hose must be changed within the prescribed time.
• Only use the type of gas and cylinder indicated in these instructions.
• Contact your gas supplier for instructions on how to use their product.
• Replace the gas set point in the open air only or in a well-ventilated area away from open flames and
sources of ignition.
• The gas cylinder must always be used in an upright position.
• Turn off the heater by turning the switch N fully clockwise to the OFF position.
• Close the gas valve and connect the regulator to the cylinder.
• Tighten all fittings securely using a suitable spanner where necessary.
• The minimum distance between the appliance and the gas cylinder is 50cm.
• Check the connections for leaks using soapy water. If you find a leak, tighten the gasket and retest.
NOTE
: Please use 13kg gas cylinders or 6kg compact cylinders of butane or propane that comply with
the current standard. Use a regulator with a safety rating of 37mbar for Propane or 28mbar for Butane.
The connection must be made using a 1.5m (maximum) supply hose and G1/2 screw connection:
make sure that the hose is not deformed, that the connection joint corresponds and that it is in good
condition. The hose must not be subjected to excessive twisting or bending. Change the supply hose
before the expiry date or when it is damaged.