ALIBI ALI-TS4002R Quick Installation Manual Download Page 5

5

www.observint.com

© 2019 Observint Technologies. All rights reserved.

SHARPNESS: Sharpness determines the amount of detail an imaging system can reproduce. You can set the 
SHARPNESS value from 1 to 9.

SATURATION: Adjust this feature to change the color saturation. The value ranges from 1 to 9.

DNR (Digital Noise Reduction): Use DNR function to decrease the noise in the image, especially when 
capturing moving images in poor light conditions, to produce a sharper image. You can set the DNR value 
from 1 to 9.

MIRROR: This feature is used to reflect the image. MIRROR can be set to OFF, H, V, and HV.

OFF: The mirror function is disabled.
H: The image flips 180° horizontally.
V: The image flips 180° vertically.
HV: The image flips 180° both horizontally and vertically.

FACTORY DEFAULT

Click 

Iris+

 to enter the submenu, and click 

OK

 to reset all the settings to the factory default. Click 

Cancel

 

to return to the menu without resetting the camera. 

EXIT

Move the cursor to EXIT and click Iris+ to exit the menu without saving.

SAVE & EXIT

Move the cursor to 

SAVE & EXIT

, and click 

Iris+

 to save the settings and exit the menu. If new settings are 

not saved, they remain in effect only until the camera is powered off or reset. 

Specifications 

C amera

Image Sensor

2MP CMOS image sensor

Signal System

PAL / NTSC

Effective Pixels

1920 (H) × 1080 (V)

Min. illumination

0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR

Shutter Time

1/25 (1/30) s ~ 1/50,000 s

Lens

2.8 ~ 12 mm @ F1.4

Angle of view: 102.25° ~ 32°

Lens Mount

Φ14

Day & Night

ICR

Angle Adjustment

Pan: 0° to 360°, Tilt: 0° to 90°, Rotation: 0° to 360°

Synchronization

Internal synchronization

Video Frame Rate

1080p @ 25 fps / 1080p @ 30 fps

HD Video Output

1 analog HD output

S/N Ratio

> 62 dB

General

Operating Conditions

-40 °F ~ 140 °F (-40 °C ~ 60 °C), Humidity 90% or less (non-condensation)

Power Supply

12 Vdc ± 15%

Power Consumption

Max. 4 W

Protection Level

IP66

IR Range

Up to 130 ft (40 m)

Dimensions

3.62” × 3.34” × 3.34” (92 mm × 84.8 mm × 269.6 mm)

Weight

Approx. 1.98 lb (900 g)

Cleaning

Clean the camera with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time. 

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

Troubleshooting

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 

- Check the video signal cable connection to the monitor. 

- Check camera settings to verify the video resolution mode of the 

   camera and recorder match

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.

- Adjust the monitor controls, if necessary. 

- If the camera is facing a very strong light, change the camera position.

- Adjust the lens focus.

The screen is dark.

- Adjust the contrast control of the monitor.

- If you have an intermediate device, set the impedance (75 Ω / Hi-Z)  

   properly, and check the cable connections.

The camera is not working properly and 

the surface of the camera is hot.

- Verify that the camera is correctly connected to an appropriate regulated  

   power source.

The image on the monitor flickers

- Make sure that the camera isn’t facing direct sunlight or fluorescent light.  

   If necessary,change the camera position.