2
www.observint.com
4.
If attaching the camera directly to a wall or ceiling:
Anchor the mounting base to the
surface with appropriate fasteners. If the camera drop cable will be routed through a cable channel,
make sure it is in place before securing the mounting plate to the surface.
Cable
Channel (2
)
If using the ALI-AJ6 junction box:
Reattach the mounting plate to the junction box.
If using the ALI-AF1 flange adapter:
Attach the flange adapter to the pedestal or conduit.
5.
Reattach the camera to the camera mounting plate.
u
Position the camera assembly onto the mounting plate such that the lip on the black ring
attached to the enclosure slips under the tabs on the mounting plate.
Mounting plate
u
Tabs
Cable channel
v
Slide the clip plate out.
v
y
x
Clip Plate
Mounting plate
Enclosure
Push the enclosure into the mounting plate until it is fully seated.
x
Slide the clip plate in so that it catches the lip of the black ring on the encloser.
y
Tighten the clip plate screw until it is just snug.
6.
Connect the far end of the video extension cable to a monitoring device, such as a surveillance
monitor or HD-TVI DVR.
7.
Connect the far end of the power extension cable to a power supply, then apply power to the
camera through the power extension cable.
8.
While observing video from the camera on a monitor, aim the camera at your surveillance target.
See the figure below for adjustment ranges.
Pan: 0 ~ 3600
Tilt: 0 ~ 900
Rotation: 0 ~ 750
9.
Tighten the clip plate screw until it is to hold the camera in place.
Cleaning Instructions
Clean the camera dome with an approved glass cleaning solution and a lint free cloth.
•
Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a
soft cloth.
•
Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing.
These may cause damage to the surface over time.
CAUTION
Do not use benzene, thinner or other chemical products on the camera assembly; these may
dissolve the paint and promote damage of the surfaces. Before using any chemical product,
carefully follow the accompanying instructions.
Specifications
Camera
Image Sensor
2MP CMOS image sensor
Signal System
HD-TVI
Effective Pixels
1920(H) * 1080(V)
Min. illumination
0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR
Shutter Time
1/30s to 1/50,000s
Lens
3.6 mm, 82.2° field of view
Lens Mount
M12
Day & Night
ICR
Angle Adjustment
Pan: 0 - 360°, Tilt: 0 - 75°, Rotation: 0 - 360°
Synchronization
Internal synchronization
Video Frame Rate
1080p @ 30 fps
HD Video Output
1 Analog HD output
S/N Ratio
> 62 dB
General
Operating Conditions
-40 °F ~ 140 °F (-40 °C ~ 60 °C), Humidity 90% or less (non-condensing)
Power Supply
12 Vdc ± 15%
Power Consumption
Max. 4W
Protection Level
IP66
IR Range
Up to 65 ft (20 m)
Dimension
3.53” × 2.33” (89.6 mm × 59.1 mm)
Weight
12 oz (340 g)
Troubleshooting
Problem
Possible Cause
Nothing appears on the screen
- Check the power connection.
- Check the video signal cable connection to the monitor.
The video image is dim or not clear.
- If the camera lens is dirty, clean it with a soft, clean cloth.
- Adjust the monitor controls, if necessary.
- If the camera is facing a very strong light, change the camera position.
- Adjust the lens focus.
The screen is dark.
- Adjust the contrast control of the monitor.
- If you have an intermediate device, set the impedance (75 Ω /Hi-Z)
properly, and check the cable connections.
The camera is not working properly and the
surface of the camera is hot.
- Verify that the camera is correctly connected to an appropriate regulated
power source.
The image on the monitor flickers
- Make sure that the camera isn’t facing direct sunlight or fluorescent light.
If necessary,change the camera position.
© 2016 Observint Technologies. All rights reserved.