ALIBI ALI-TP2013VR Quick Installation Manual Download Page 5

5

www.observint.com

© 2016 Observint Technologies. All rights reserved.

 

INFRARED

: Select this option to turn on/off the IR LED in response to the light level in the field 

of view.

 

SMART IR

: Use the Smart IR feature is to adjust the light to its most suitable intensity, and to 

prevent the image from over exposure. The SMART IR value can be adjusted from 0 to 3. The 
higher the value, the more obvious the effects are. If set to 0, SMART IR is disabled. 

VIDEO SETTING Menu

Move the cursor to VIDEO SETTING and press the confirm button to enter the submenu. In this menu you 
can adjust CONTRAST, SHARPNESS, COLOR GAIN, DNR and MIRROR settings.

• 

CONTRAST

: This feature enhances the difference in color and light between parts of an image. You 

can set the CONTRAST value from 1 to 10.

• 

SHARPNESS

: Sharpness determines the amount of detail an imaging system can reproduce. You can 

set the SHARPNESS value from 1 to 10.

• 

COLOR

 

GAIN

: Adjust this feature to change the saturation of the color. The value ranges from 1 to 10.

• 

DNR

 (Digital Noise Reduction): The DNR function can decrease the noise effect, especially when 

capturing moving images in low light conditions and delivering more accurate and sharp image 
quality. You can set the DNR value from 1 to 10.

• 

MIRROR

: DEFAULT, H, V, and HV are selectable for mirror. 

 

DEFAULT

: The mirror function is disabled. 

 

H

: The image is reflected horizontally. 

 

V

: The image is reflected vertically.

 

HV

: The image is reflected both horizontally and vertically. 

RESET

• 

RESET

: Reset all the settings to the default.  

SAVE &EXIT 

• 

SAVE &EXIT

:

 

To save your new settings, move the cursor to SAVE &EXIT and click OK to save the 

setting and exit the menu. 

Specifications 

Camera

Image Sensor

3MP CMOS Image Sensor

Effective Pixels

2052 (H)*1536 (V)

Min. illumination

0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR

Shutter Time

1/25 s to 1/50,000 s

Lens

Motorized  VF: 2.8 mm 

 12 mm @ F1.2

Lens Mount

ф14

Day & Night

ICR

Angle Adjustment

Pan: 0° ~ 340°; Tilt: 0° ~ 75°; Rotate: 0° ~ 355°

Synchronization

Internal Synchronization

WDR

> 120 dB

Video Frame Rate

1920 × 1536 @ 18 fps

HD Video Output

1 Analog HD output

S/N Ratio

> 62 dB

Menu

AGC

Supported

D/N Mode

Color / BW / SMART

White Balance

ATW / MWB

BLC

Supported

Functions

Wide Dynamic Range, Digital noise reduction, Digital zoom (62x), Mirror, Defect pixel correction, 

SMART IR

General

Operating Conditions

-40 °F ~ 140 °F (-40 °C ~ 60 °C ), Humidity 90% or less (non-condensing)

Power Supply

12 Vdc ± 15%, / 24 Vac ± 15%

Power Consumption

Max. 6.5 W

Protection Level

IP66

IR Range

130 ft max. (40 m max)

Communication

Up the coax

Dimensions

φ5.72” × 4.89” (φ145.2 mm × 124.1 mm) 

Weight

3.53 lb (1600 g)

Cleaning Instructions

• 

Dust or grease on the dome cover will cause IR reflection. Do not remove the dome cover film until the 
installation is finished. If there is dust or grease on the dome cover, clean the dome cover with clean 
soft cloth and isopropyl alcohol.

• 

Make sure that there is no reflective surface too close to the camera lens. The IR light from the camera 
may reflect back into the lens causing reflection.

• 

The foam ring around the lens must be seated flush against the inner surface of the bubble to isolate 
the lens from the IR LEDS. Fasten the dome cover to camera body so that the foam ring and the dome 
cover are attached seamlessly.

Clean the camera dome with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time.  

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

Troubleshooting

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 

- Check the video signal cable connection to the monitor. 

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.

- Adjust the monitor controls, if necessary. 

- If the camera is facing a very strong light, change the camera position.

- Adjust the lens focus.

The screen is dark.

- Adjust the contrast control of the monitor.

- If you have an intermediate device, set the impedance (75 Ω /Hi-Z)  

   properly, and check the cable connections.

The camera is not working properly and 

the surface of the camera is hot.

- Verify that the camera is correctly connected to an appropriate regulated  

   power source.

The image on the monitor flickers

- Make sure that the camera isn’t facing direct sunlight or fluorescent light.  

   If necessary,change the camera position.

Reviews: