Power supply
Attention! The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and /or damage to property. Overhead rigging
required extensive experience! Working load limits should be respected, Certified
installation materials should be used, the installed device should be inspected regularly for
safety.
Make sure the area below the installation place is free from unwanted persons during
rigging, de-rigging and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or
liquids. The fixture must be fixed at least 20cm from surrounding walls
The device should be installed out of reach of people and outside areas where persons
may walk by or be seated.
The device should be well fixed; a free swinging mounting is dangerous and may not be
considered!
Do not cover any ventilation opening as this may result in overheating
Before the first time use, it must be inspected by professional staff to make sure safety,
inspection regularly every year.
C able(E U )
B rown
L ight blue
Y ellow/G reen
C able(U S )
B lac k
White
Y ellow/G reen
P in
L ive
Neutral
E arth
International
L
N
Please use the attached power, note that power
voltage and frequency are the same as the marked
voltage and frequency of device when connecting
power. Every device’s
power should be connected
s e parate ly, s o that de vic e c an be c ontrolle d
individually.
Before rigging make sure that installation area can hold the 10 times weight of device. Using
the steel rope which can hold 12 times weight of device, through the eye-bolt for assisting
hang installment.
OVERHEAD RIGGING