ARDI SERVICE PARTS LIST CONTINUED:

 

Main Power Switch 

210-0021 

Power Cord 

210-0287 

Strain Relief 

200-0009 

Used to secure power cord 

Refrigerator Control 

210-0

551

 

Food Pan 1/6 x 4 

290-0162 

Pan Holder 

130-1043 

Summary of Contents for ARDI

Page 1: ...File name ARDI Service Manual pub Last revised March 6th 2009 ARDI SERVICE AND PARTS MANUAL ...

Page 2: ...as been tripped If the latter is the case then switching the unit off for fifteen minutes then on again should solve the problem CONDENSER FAN NOT RUNNING Is the compressor running but not the condenser fan If the compressor is running then the condenser fan should be running Verify that power is being supplied to the fan motor and that the fan blades rotate freely Check for debris leaves paper gr...

Page 3: ...fully stocked or only partially filled then the unit will need to work harder Air does not hold temperature products do If there is no product inside the refrigerator the unit will cycle ON and OFF several times per hour If the unit is fully stocked the run time will be extended but also the off time allowing the compressor to cool down properly between cycles This will help the unit to run more e...

Page 4: ...it Please refer to the picture and associated text for reference and identification Condensing Unit 260 0104 Drier 220 0030 Sight Glass 220 0014 REFRIGERANT COMPRESSOR 260 0055 CAPACITOR 210 0393 RELAY 210 0392 SAFETY OVERLOAD 210 0391 NOTE PART NUMBERS 210 0391 210 0392 AND 210 0393 ARE REPLACEMENT PARTS FOR THE COMPRESSOR ASSEMBLY ...

Page 5: ...RDI SERVICE PARTS LIST CONTINUED Main Power Switch 210 0021 Power Cord 210 0287 Strain Relief 200 0009 Used to secure power cord Refrigerator Control 210 0551 Food Pan 1 6 x 4 290 0162 Pan Holder 130 1043 ...

Page 6: ...6 ...

Page 7: ...scription of the problem The model number and serial number can be found on a plate located either on the underside of the top cover or on the body behind the removable louvered front panel REFRIGERATION REFRIGERANT 134A 13OZ SUCTION PRESSURE TEMP 18 PSI 20 F ACCEPTABLE RANGE 12 21 PS I COIL TEMP 10 F 24 F LIQUID PRESSURE TEMP 125 PSI 100 F ACCEPTABLE RANGE 125 147 PSI AMBIENT TEMP 80 F 90 F 170 P...