1 8
Minigraf 4
Table 6.6.A - Ordinary Maintenance
Maintenance
V-nail driver blade
Movable parts lubrication
V-nail claw heads
“L” shaped supports (V-nail guide)
Description
Replacement every 1.000.000 V-nails shot
Lubricate the driver blade every 200
working hours
Replacement every 5.000.000 V-nails shot
Replacement every 5.000.000 V-nails shot
Machine state
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
6.7
EXTRAORDINARY MAINTENANCE
Listed below are the operations that need the intervention of ALFAMACCHINE , your distributors Technical Assistance (see
the paragraph 1.2) or by qualified staff authorized by the Producer
The extraordinary maintenance includes interventions to be performed in exceptional cases:
•
Breakage
•
Revisions
MAINTENANCE
Valves and Reducers
Frontal and vertical clamp gaskets
DESCRIPTION
Suggested replacement every 6/8 million
of V-nails shot
Replacement in case of air leaks
MACHINE STATE
Isolation for maintenance
Isolation for maintenance
TAB. 6.7 A