Alfaa EcoStream Lite Operation And Maintenance Manual Download Page 3

 

OVERVIEW

 

Each UV system is designed to treat water at specified flow rates as outlined in the specification 
sheet. All EcoStream units are provided with two main component parts, specifically the ultraviolet 
reactor chamber and the main controller. 

Reactor Chamber 

The reactor chamber is manufactured from stainless steel 304L and houses the ultraviolet lamp and 
quartz sleeve. All EcoStream Lite UV systems use only a single UV lamp. The lamps are of a special 
high intensity, high output germicidal type. The chamber is designed to mount both horizontally or 
vertically and should be secured to a suitable support. 

Power Supply 

The main power supply is connected to the chamber via 1.5 meters of cable to allow for application 
flexibility. In case an extension is required, 

do not cut the cable

. Use an extension box or surface 

mount electrical socket. 

 

PRODUCT APPLICATION 

Ultraviolet disinfection provides a simple, inexpensive way of destroying bacteria, mold, virus, algae 
and fungi without the use of heat or chemicals. Each EcoStream system is designed to achieve a 
specific energy dose to properly destroy microorganisms. 

UV Disinfection is affected by many factors and the following should be looked at prior to the 
installation of the UV system: 

1.

 

UV Transmission (transmittance) deals with the effectiveness in which the 254 nanometer 
wavelength of ultraviolet light is transmitted through the water. The higher the transparency of 
the water, the more effective the UV system becomes.  

As a general guideline, the following are some typical UV transmission rates: 

Deionized or reverse osmosis water   

: 90 - 98% 

Typical filtered fresh water   

 

: 85 - 94% 

Lakes, wells, or other private sources 

: 70 - 90% 

 

 

*** WARNING -- DO NOT UNDERSIZE UNITS *** 

If exact transmission quality needs to be determined, have samples tested at a suitable lab using 
a proper spectrophotometer (@ 254nm). Alternatively, you may contact Alfaa UV for a sample 
analysis. 

2.

 

Suspended Solids will act against a UV system by effectively shielding microorganisms from the 
ultraviolet light. Dirt, rust, turbidity, etc. all have the ability to block out the UV light. It is 
absolutely necessary to properly control the level of suspended solids by properly pre-filtering 
the liquid prior to disinfection (pre-filtration down to 5 micron is considered the minimum). 

3.

 

Total Dissolved Solids of around 500 ppm can drastically reduce the rated flow rate of the unit by 
absorbing UV energy. Proper pretreatment of high TDS levels must be taken into account. 

Summary of Contents for EcoStream Lite

Page 1: ...OPERATIONS AND MAINTENANCE MANUAL EcoStream Lite...

Page 2: ...not approved recommended or sold by the manufacturer dealer may cause an unsafe condition 7 Intended for indoor use only Do not install this UV disinfection system where it will be exposed to the weat...

Page 3: ...is affected by many factors and the following should be looked at prior to the installation of the UV system 1 UV Transmission transmittance deals with the effectiveness in which the 254 nanometer wa...

Page 4: ...n on the inlet valve and SLOWLY fill the reactor chamber with water Once the chamber is full check for leaks from the fittings If a leak is evident drain system and reconnect the fittings 5 In case th...

Page 5: ...f the reactor Figure 1 Make sure to remove the QG sealing O ring and keep it carefully Figure 2 4 Carefully slide the sleeve out of chamber Figure 3 In case it is initially tight gently try rotating t...

Page 6: ...try twisting the connector as it will break Pull only on the lamp pins connector Wipe off any oils with alcohol and a soft cloth Warning Depending on when the system was powered down the UV lamp migh...

Page 7: ...ull and void if unauthorized repairs alteration or modification is made to be product 4 The serial number must not be defaced or altered in any way 5 The Warranty extended herein is in lieu of all imp...

Page 8: ...l W Mumbai 400013 India Tel 91 22 66612300 Fax 91 22 66612333 E Mail indsales alfauv com Website www alfauv com Service Office 307 A2 Shah Nahar Industrial Estate Lower Parel W Mumbai 400013 India Tel...