3 Installation
Read the instructions carefully and pay special attention to the warnings.
The installation variation below is ONLY A SUGGESTION. It is important that you contact your local regulatory agency
for acceptance of your installation.
3.3
Important Installation Information
Step 1
Pre-use check:
1. Supply compressed air to the actuator.
2. Open and close the valve several times to ensure that it
operates smoothly.
Pay special attention to the warnings!
Air (NO)
Open/close!
TD 474-003
Step 2
NOTE!
When installing C.I.P. drain pipe on the Vacuum Breaker discharge
port, ensure that an atmosphere break exists no lower than the
lowest point of the Vacuum Breaker. Ensure that the Vacuum
Breaker is situated 12" above the highest point of the raw product
pipeline on the pasteurized side.
C.I.P. Drain or atmospheric
port
TD 474-005
Pa
s
teuri
z
ed
Raw Product
12
”
minimum
HTST pasteurization system
Step 3
During product process, port acts as an atmospheric break in
case of power loss/failure. During C.I.P, the port acts as a C.I.P.
drain port.
Suggested installation
only
TD 474-006
Atmospheric break