4 Installation
Study the instructions carefully and pay special attention to the warnings!
The valve has ends for welding as standard but can also be supplied with fittings.
4.3
General installation
Step 1
-
Always read the technical data thoroughly (see 7.1 Technical data).
-
Always release compressed air after use.
-
Never touch the clip assembly or the actuator piston rod if the actuator is supplied with compressed air
(see the warning label)
CAUTION!
-
Fit the supplied warning label on the valve so that it is clearly visible.
-
Alfa Laval cannot be held responsible for incorrect installation
NOTE!
-
The leakage outlet must be turned downwards!
Step 2
Avoid stresses to the valve as this can result in deformation of
the sealing area and misfunction of the valve (leakage or faulty
indication).
Pay special attention to:
-
Vibrations
-
Thermal expansion of the tubes (especially at long tube lengths)
-
Excessive welding
-
Overloading of the pipelines
NOTE!
Please follow Alfa Laval installation guidelines (literature code
ESE00040).
Risk of damage!
2317-0018
!
Step 3
Fittings
Ensure that the connections are tight.
Remember seal rings!
2317-0019
Step 4
Valve Pneumatic Connections
ThinkTop
Fitting ID
Actuator
Fitting ID
Out 1A
Air connection 2 (blue)
Out 2
Air connection 3 (yellow)
Out 3
Air connection 1 (red)
Air connection: R 1/8” (BSP).
2317-0020
AC1
AC2
AC3
AC1 =
Air connection 1 (red) upper seat push
AC2 =
Air connection 2 (blue) open/close
AC3 =
Air connection 3 (yellow) lower seat push