CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | 417.831.1411
4 Operation
Pay attention to possible breakdown.
Read the instructions carefully.
LKB-F: With flange connection.
NC = Normally closed. NO = Normally open. A/A = Air/air activated.
S
Stteepp 66
O
Oppeerraattiioonn bbyy m
meeaannss ooff rreegguullaattiinngg hhaannddllee::
1. Manual flow regulation because of infinite locking positions.
2. Loosen the handle, rotate it and tighten again.
Closed valve
Open valve
Open valve
Closed valve
4.2 Troubleshooting
S
Stteepp 11
N
NO
OTTE
E!!
Read the maintenance instructions carefully before replacing worn parts. - See chapter 5.1 General maintenance
P
Prroobblleem
m
C
Caauussee//rreessuulltt
R
Reeppaaiirr
- External leakage
- Internal leakage by closed valve
(normal wear)
- Worn seal ring
- Worn flange seal ring (LKB-F)
Replace the seal ring and the bushes
- External leakage
- Internal leakage by closed valve (too
early)
- High pressure
- High temperature
- Aggressive liquids
- Many activations
- Change rubber grade
- Change the operating conditions
- Difficult to open/close
- Damage to disc connection (high
torque)
Incorrect seal ring (swelling)
Replace by a seal ring of a different rubber
grade
Difficult to open/close
- 90° displacement of the actuator
- Incorrect actuator function (NC,NO)
- Worn actuator bearings
- Dirt penetration into the actuator
- Fit correctly (see chapter 3.4 Fitting
actuator/bracket/handle on the valve
(optional extras))
- Change from NC to NO or vice versa
- Replace the bearings
- Service the actuator
15