8
Installation
8.2
Electrical Installation
The following must be considered when
installing the electrical system:
•
Cables must be marked at both ends
according to the illustration.
•
Screened cables must be used for input
signals from the temperature sensor, flow
switch, and high temperature switch.
•
Power cables and fuses must be
dimensioned for the installation capacity.
G025211A
•
The screened cables must be kept well
away from the power cables. The minimum
specified distance is 300 mm.
•
Screens must be earthed as close as
possible to the earth bar.
•
Cables to the external alarm panel and for
series computer communication must be
installed according to the manufacturer’s
recommendations.
G003141A