4 Operation
11
Read the instruction carefully and pay special attention to the warnings!
4.1 Operation/Control
Step 1
Always read the technical data thoroughly. See chapter 6 Technical Data
CAUTION
Alfa Laval cannot be held responsible for incorrect operation/control.
Step 2
Never touch the tank cleaning machine or the pipelines when pumping hot liquids.
Step 3
Initial Startup
Every Alfa Laval GJ PF-FT that ships is accompanied by a Birth Certificate. This document indicates how the machine
performed in our testing tank before it shipped based on the operating conditions supplied to Alfa Laval Gamajet. To ensure
the longest possible life of the machine,
please verify the operating conditions and, most importantly, the machine’s cycle
time. The cycle time can be measured by, first, picking a fixed point inside of a vessel as a reference and, second, timing
how long it takes the same nozzle to pass back over that point in the vessel. (This, naturally, will not be the exact same spot
because the spray pattern is indexing.) The measured time in seconds directly corresponds to the machines full cycle time in
minutes. In other words, a single 10-second rotation translates to a 10 minute full cycle time.