4

20KG Grease Kit

OWNER’S TECHNICAL MANUAL

G100120

General Safety Regulations

When the pump is connected to the compressed air supply:
1.  The compressed air must be filtered to avoid dust into the pump.
2.  The maximum compressed air pressure must not exceed 0.8Mpa.
3.  To deliver grease, press the knob on the delivery nozzle. Delivery stops when the knob is released but the whole 

system remains under pressure.

4.  Position the nozzle so that the circuit can not open accidentally. Otherwise grease could leak onto the ground. 
5.  Never point the nozzle at people.
6.  Press the nozzle knob only after you are sure that the nozzle is in the right place so that the grease doesn’t leak 

onto the ground.

7.  Always cut off the air supply after use so that grease can not leak out in case one of the pump’s components break.
8.  Use only original spare parts if the pump has to be repaired or its components have to be replaced.
9.  Ensure the tightness of all joints and screwed unions.
10.  When not loading, cut off compressed air to stop pump.
11.  Do not use the pump near open flames. Do not smoke during this operation.
12.  Wear oil-proof gloves.
13.  The pump can be used only to deliver grease. Do not use the pump for any other purpose.

How To Use

Pump Installation
1.
  When the pump is applied to a high viscosity grease, or used in low temperature, a grease follower plate is  

recommended to avoid air pockets and to get the most out of your grease. The follower plate, which is pulled 

towards the bottom of the drum by suction pressure produced by the air operated pump, compress the grease, 

preventing the formation of air pockets which may cause a blockage in delivery. And the follower plate will always 

keep the grease clean to preserve its characteristics and also enable the grease to be collected from the bottom  

of the drum to avoid waste.

2.  Loosen the bung adaptor or wall bracket adaptor star nut. Slide the bung adaptor off of the suction tube.
3.  Carefully place the pump through the bung adaptor and the follower plate. Then tighten the star nut firmly in order  

to attach the pump.

Connection of the Air Inlet Line
1.
  Air inlet connection is 1/4’’ quick plug in all versions.
2.  Compressed air connection (to be supplied by the customer) should be done using suitable tubes.
3.  A compressed air treatment unit (filter and regulator) is recommended to be attached to the pump.  

In order to improve the efficiency of the pump, the installation of a lubricator is also recommended.

Connection of the Regulator
The lubricator (I) must be placed as close as possible to the air inlet, followed 

by the pressure regulator (II) and finally, the filter (III). In the case of pumps  

not installed on wall support it is very important to equip the pump’s air inlet 

with an adaptor for quick coupling and the air inlet hose with a quick connector.

Summary of Contents for EL SERIES

Page 1: ...less pneumatic greasing solution Should the need ever arise spare parts are readily available upon request Item No G100110 Grease Pump Ratio 50 1 Operating pressure 30 150psi 2 10bar Maximum air inlet pressure 150psi 10bar Air consumption per minute 900 10bar 100L Tube diameter 30mm Suction tube length 480mm Suitable for drum 20kgs Air inlet connection 1 4 quick plug Oil delivery connection Male 1...

Page 2: ...ng this product carefully check that it will operate properly and perform its intended function Check for damaged parts and any other conditions that may affect the operation of this product Replace damaged or worn parts immediately 5 Do not overreach Keep proper footing and balance at all times to prevent tripping falling back injury etc 6 DO NOT use the equipment when tired or under the influenc...

Page 3: ... and fill the drum 2 Clean or recharge silencer 3 Use clean grease 4 Replace damaged elements Grease leaks through the air exhaust Seal set 28 damaged Replace damaged elements If the pump has anything wrong please contact Alemlube We do not recommend customers repairing the pump themselves Storage and Maintenance Pumps are delivered in appropriate cardboard boxes Packaging material should be prope...

Page 4: ...d only to deliver grease Do not use the pump for any other purpose How To Use Pump Installation 1 When the pump is applied to a high viscosity grease or used in low temperature a grease follower plate is recommended to avoid air pockets and to get the most out of your grease The follower plate which is pulled towards the bottom of the drum by suction pressure produced by the air operated pump comp...

Page 5: ... the compressed air feed is connected to the appropriate work pressure level 5 10 bar the pump will start automatically when the nozzle or nozzle situated at the end of the grease delivery circuit is opened To stop the pump simply close the nozzle or disconnect the air inlet line Connect the Pump with other Accessories Part No Description 1 Grease Pump 2 Drum Cover 3 Grease Control Valve 4 Hose wi...

Page 6: ...your hand or body Be sure equipment safety devices are operating properly before each use 4 Any misopertation of the system equipment or accessories such as overpressure modifying parts using incompatible chemicals and fluids or using worn or damaged parts can cause them to rupture and result in fluid injection splashing in the eyes or on the skin or other serious injury or fire explosion or prope...

Page 7: ... Drum Cover and Follower Plate List Put the drum cover onto the drum and tighten the three locks crew Put the follower plate into the grease drum on the grease surface horizontally pressure it as much as possible to exhaust the air between follower plate and grease 50 1 Ratio pump G100110 Drum application 20kgs Drum cover G100110 52 Follower plate G100110 53 1 4 4m connection hose G100110 54 Greas...

Page 8: ...110 12 Baffle 1 G100110 13 Piston 1 G100110 14 O Ring 2 G100110 15 Shaft 1 G100110 16 Shaft 1 G100110 17 Sealing Ring 1 G100110 18 Guiding Ring 1 G100110 19 Connector 1 G100110 20 Silencer 1 G100110 21 O Ring 2 G100110 22 Quick Coupling 1 G100110 23 Silencer 1 G100110 24 Circlip 1 G100110 25 Outlet 1 G100110 26 Air Control Center 1 G100110 27 Washer 1 G100110 28 O Ring 1 G100110 29 Valve Seat 1 G1...

Page 9: ...hing are worn at all times in the vicinity of the control handle Failure to follow these recommendations may result in serious injury or death CAUTION Maximum fluid pressure is 5 800psi 400bar Under no circumstances should the control handle be aimed at any person Personal injury may result Product Description The control handles are used for dispensing automotive lubricants Operation 1 Connect th...

Page 10: ...e 1 O300130 20 Valve Seat 1 O300130 21 Nut 1 O300130 22 O Ring 1 O300130 23 Block Ring 1 O300130 24 Axis Tile 2 O300130 25 Axes 1 O300130 26 Liner Ring 1 O300130 27 Hexad Bolt 4 O300130 28 Join Pipe 2 O300130 29 Join Piece 2 O300130 30 Adjust Bolt 1 O300130 31 Clump Weight 1 O300130 32 Z swivel 1 O300130 1 O300130 2 O300130 3 O300130 4 O300130 7 O300130 8 O300130 30 O300130 6 O300130 9 O300130 10 ...

Reviews: