background image

ALEKO AR1450 SLIDING GATE OPENER 

14

11. Trouble Shooting 

S

The wire connector terminal block 

becomes loose.

Check wire connector terminal block make 

sure it is plugged in terminal block 10 (X8). 

The limit switch wire connector terminal 

block becomes loose. 

Check limit switch wire connector terminal 

block make sure it is plugged in terminal 

block 9 (X9). 

Check the limit switch mode. 

Motor only runs in one direction. 

The electric component on the control 

board such as Q2, Q91 or Q92 may be 

damaged.

Replace the electric component Q2, Q91 or 

Q92 (BTA16/600) or replace the board. 

By pressing button 1(button 2 or button 3) 

which has been programmed to open the 

gate, press the same button again to stop 

the gate in required position, but the gate 

will auto-close immediately. 

The auto-close time is too short. 

Reset the auto-close time. See

 Set auto-

close function

 section. 

When you use button 4 of remote control 

to open the gate, gate travels too short.

The width of pedestrian mode is too 

narrow. 

Reset the width of pedestrian mode. See 

Set

width of pedestrian mode 

section.

When you use button 4 of remote control 

to open the gate, but the gate will auto-

close immediately. 

The auto-close time of pedestrian mode 

is too short. 

Reset the auto-close time of pedestrian. See 

Set auto-close function of pedestrian 

mode

section.

The limit switch wire connector terminal 

block becomes loose. 

Check the limit switch mode (see table 1 DIP 

switch). 

Connecting wires or terminal blocks are 

too loose. 

Check the connecting wires and terminal 

blocks.

The electric component on the control 

board such as Q2, Q91 or Q92 may be 

damaged.

Replace the electric component Q2, Q91 or 

Q92 (BTA16/600) or replace the board. 

The gate will not open or close. 

 

c t

 

The indicator light of remote control does 

not light. 

Check the batteries on your remote control. 

Remote control is not suitable for 

receiver.  

After making sure the codes are correct, 

erase remote controls and then re-program 

the codes in the device. See

 Adding extra 

remote controls (learning) 

section.

Remote control does not work 

Broken receive board 

Replace receive board. 

The Force Adj. (VR1) is adjusted too 

small.

Check the Force Adj. (VR1). Adjust VR1 to 

increase force. 

When you open the gate by using button 

1(button 2 or button 3) which has been 

programmed, gate will stop in mid-travel 

or reverse before reaching the fully limit 

position.

o  

The remote control operating distance is 

too short. 

Signals are shielded by the gate. 

Link a new antenna (1~1.2m BVR 0.75mm

2

see parts list) to the old antenna. Then fix the 

antenna on the wall vertically, make sure the 

total height from the top of antenna to the 

ground is approx. 1.5m. 

The gate opens, but stops and will not 

return.

1. Please note the two magnet brackets 

(fixed plate) are different: one is higher 

and another is lower. Please try to 

exchange the two brackets position. 

2. Please try to exchange the limit switch 

wires CL (close) and OP (open). 

There are two reed switches inside the 

magnetic limit switch: one is upper and 

another is lower. Maybe the magnet position 

was installed in the middle so it inducts both 

reed switches. Solution: adjust the magnet 

upper or lower. 

Summary of Contents for Lockmaster DKC400U

Page 1: ...www Gatemotors com Support Gatemotors com Tel 305 809 6301 Lockmaster DKC400UY Lockmaster DKC400U Aleko AR 1450...

Page 2: ...UAL 1 OUTLINE 1 Important safety information 3 2 Main features 3 3 Main technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 4 6 Connecting 7 7 Control 10 8 Ch...

Page 3: ...AR 1450 2...

Page 4: ...EKO tr3pc8 4 9 Base plate for receiver limit switch sensor ALEKO tr3bp9 1 10 Base plate for control board ALEKO tr3bp10 1 11 Plastic clip ALEKO tr3pc11 4 12 Receiver ALEKO tr3rec12 1 13 Large bracket...

Page 5: ...se of various tools shown below Other tools may be required as needed for the installation of the concrete pad and electrical connection Table 3 Required Tools for Installation Screwdriver Tape Measur...

Page 6: ...has access to it Be careful when in close proximity to moving parts where hands or fingers could be pinched Do not allow control devices to be placed so that a person can access them by reaching thro...

Page 7: ...witch on the motor automatically when the temperature is lower than 85 C 5 C 5 Installation and adjustment The AR 1450 rack driven gate operator operates by forcing a drive rack past a drive gear The...

Page 8: ...e is possible mount the gate operator on installation pad as shown in Fig 2 Check the operator and make sure it is lined up with the gate Nut Bolt Anchor Nut Spring washer Plain washer Gear Gate opera...

Page 9: ...the sliding gate manually to pre determine the position Solder the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close po...

Page 10: ...IP Switch 1 Limit switch NC normally closed or NO normally open DIP Switch 1 ON NO OFF NC This mode enables user to set the board to work with motor with NC or NO limit switch NOTE Factory default set...

Page 11: ...inside of the property where the opener is installed DIP Switch 5 OFF Opens to the right DIP Switch 5 ON Opens to the left Note If opening is to the left the Limit Switch wires on the control board y...

Page 12: ...8 ON Blue Button is Working OFF Blue Button is Not Working 2 Potentiometers The left potentiometer is to adjust the CLOSE stall force of the gate opener The right Potentiometer is used to adjust the...

Page 13: ...meter in counter clockwise direction Turning the stall force potentiometer toward to Light position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will...

Page 14: ...Residential Sliding Gate Operator AR1450 Optional Equipment Installation Procedures O O O O O O O O O O O O Blue Brown Black White Green Brown Red Black 13...

Page 15: ...too loose Check the connecting wires and terminal blocks The electric component on the control board such as Q2 Q91 or Q92 may be damaged Replace the electric component Q2 Q91 or Q92 BTA16 600 or repl...

Page 16: ...Gate1Access LLC P O box 121776 Clermont Fl 34712 sales Gatemotors com www Gatemotors com 2011 2012 Aleko Lockmaster All Rights Reserved...

Reviews: