3.3 Positioning:

Indoor unit:

You may choose to suspend the weather station from a wall using a 

simple screw or to use it as a desk model using the supplied table stand. 

In any case, never place the weather station in direct sunlight or nest to a 

heat-radiating lamp or stove.

Outdoor unit:

You may choose to place the outdoor unit onto a flat surface (e.g. a fence or railing) or to mount it on a pole 

(excluded). In any case, make sure to position the unit at least 1.5 meters above the ground, standing freely 

in the rain and wind.

General installation and placement tips:

•  First check whether the outdoor unit is within range of the indoor unit before permanently installing it. 

Maintain a distance of a maximum of 30 meters between the outdoor unit and indoor unit.

•  Make sure the outdoor unit is placed at least 1.5 meters above the ground and that the unit is openly 

standing in the rain and wind.

•  For the rain meter to work as accurately as possible, the outdoor unit must be as horizontal as possible. 

To do this, use the built-in spirit level on top of the outdoor unit.

•  To be able to indicate from which direction the wind is coming from, the outdoor unit must be oriented 

towards the north. See the indication 

on top of the outdoor unit for this. Use a precise compass (ex-

cluded) to properly orientate the unit.

•  Ensure that the outdoor unit is hanging or standing freely. Particularly the wind speed meter and wind 

vane must hang in direct wind.

•  Find a location where the chance of blowing leaves is minimal. Leaves blown into the rain collector can 

block the rain meter or influence the measurement results. In any case, we recommend that you place 

the outdoor unit in such a way that it is fairly easy to remove any blown leaves and replace the batteries 

in the outdoor unit.

• 

Of course, you may first keep the outdoor unit within reach for a week to test all its functions. Only per

-

manently install the outdoor unit after everything is functioning properly. 

3.4 Clock:

Introduction

The WS-4900 is provided with a built-in DCF receiver which receives the DCF time signal from Frankfurt. 

This signal ensures that the clock shows the time very accurately, provided a strong enough signal is being 

received. 

>1,5m

N

rubber 

pads

horizontal 

setup

Summary of Contents for WS-4900

Page 1: ...e d emploi Bedienungsanleitung User Manual WS 4900 Weerstation met draadloze buitensensor Station m t o avec capteur ext rieur sans fil Wetterstation mit kabellosem Au ensensor Weather station with wi...

Page 2: ...2 NL GEBRUIKSAANWIJZING 3 FR MODE D EMPLOI 20 D BEDIENUNGSANLEITUNG 38 GB USERS MANUAL 55...

Page 3: ...uctiefou ten Een en ander ter uiteindelijke beoordeling van de importeur HOE TE HANDELEN Bemerkt u een defect raadpleeg dan eerst deze gebruiksaanwijzing of de website van Alecto Geven deze hieromtren...

Page 4: ...ind richting snelheid 13 4 8 Gevoelstemperatuur en dauwtemperatuur 13 4 8 Maanstand 14 4 9 Maximum Minimum geheugen 14 4 10 Displayverlichting 14 4 11 Ontvangstindicatie buiten unit 14 5 MAX MIN ALARM...

Page 5: ...eeft wordt op de volgende pagina s beschreven 3 Toets HISTORY toont de gegevens van de afgelopen 24 uur 4 Regentoets voor weergave van de verschillende regen parameters 5 Barometertoets voor weergave...

Page 6: ...temperatuurweergave in te stellen op graden Celsius of graden Fahrenheit 16 Toets RCC om de DCF ontvanger in of uit te schakelen 17 Batterijcompartiment voor de back up batterij 18 Aansluiting voedin...

Page 7: ...s RESET om de buiten unit opnieuw op te starten in geval van een mogelijke storing 12 Batterijcompartiment 13 Bevestigingsschroeven in geval van bevestiging aan een paal 2 3 Regenmeter 1 Regenopvangba...

Page 8: ...kking tot batterijen voor de buiten unit Omdat normale Alkaline batterijen niet of slecht presteren bij temperaturen van rond of onder 0 C is het toepassen van standaard Alkaline batterijen in de buit...

Page 9: ...gebouwde waterpas boven op de buiten unit Om aan te kunnen geven uit welke richting de wind vandaan komt moet de buiten unit op het Noor den gericht worden Zie hiervoor de aanduiding N boven op de bui...

Page 10: ...wordt weergegeven u heeft de keuze uit EN Engels FR Frans DE Duits ES Spaans of IT Italiaans druk kort op toets 11 stel met in of u de klok automatisch wilt laten omschakelen bij zomer of wintertijd...

Page 11: ...eid 1 indicatie outdoor 2 indicatie batterij zwak in de buiten unit 3 indicatie van de signaalsterkte van de buiten unit 4 temperatuur buiten 5 relatieve luchtvochtigheid buiten 4 4 Weersvoorspelling...

Page 12: ...igen in het geval u het weerstation veel hoger dan op zeenivo gebruikt add 6 In de Benelux wordt gebruik gemaakt van de hectoPascal notatie Vroeger werd de luchtdruk ook wel in bar uitgedrukt 1 mbar i...

Page 13: ...durende 2 seconden ingedrukt 2 selecteer met de gewenste eenheid 3 druk kort op toets 4 8 Gevoelstemperatuur en dauwtemperatuur 1 indicatie of de weergegeven temperatuur de Feels like de Wind Chill de...

Page 14: ...bruik de schakelaar HI LO AUTO aan de achterzijde van de binnen unit om de displayverlichting in te stellen AUTO de displayverlichting volgt het omgevingslicht bij weinig omgevingslicht is ook de disp...

Page 15: ...t u stoppen door kort op toets ALARM SNOOZE te drukken Het knipperen stopt automatisch zodra de betreffende meetwaarde weer binnen de ingestelde limiet valt of zodra u de limiet wijzigt of de alarmfun...

Page 16: ...kt wordt door een paar keer kort op toets te drukken 4 houd nu toets ingedrukt totdat na ongeveer 2 seconden ABS absoluut of REL relatief gaat knipperen 5 gebruik zodat REL relatief knippert 6 druk ko...

Page 17: ...sche apparaten die interferentie kunnen veroor zaken door draadloze communicatie TV s PC s Magnetron Als de problemen blijven bestaan reset dan zowel de binnen als de buitenunit en ontvangst signaal g...

Page 18: ...gelopen 24 uur MIN MAX temperatuur met tijd en datum Buitenshuis temperatuur meeteenheden C F weergavebereik 40 C tot 80 C 40 F tot 176 F LO bij 40 C Hi bij 80 C functioneel bereik 40 C tot 60 C 40 F...

Page 19: ...m s 180km h 97knots resolutie 0 1mph of 0 1knot of 0 1m s nauwkeurigheid 5m s 0 5m s 5m s 6 weergave eenheden gemiddeld windvlaag geheugen weergave historie van de afgelopen 24 uur MAX windvlaag met r...

Page 20: ...umis l ap probation de l importateur COMMENT PROC DER Si vous constatez un d faut veuillez d abord vous r f rer au guide de l utilisateur si le manuel ne fournit pas de r ponse veuillez contacter le f...

Page 21: ...itesse 30 4 8 Fra cheur du vent et temp rature de ros e 30 4 8 Phase lunaire 31 4 9 M moire maximale minimale 31 4 10 Eclairage d affichage 31 4 11 Indication de r ception de l unit ext rieure 31 5 AL...

Page 22: ...icher Tout ce qui figure l cran est d crit la page suivante 3 Bouton HISTORY montre les donn es des 24 derni res heures 4 Bouton pluie pour afficher les diff rents param tres de pluie 5 Bouton barom t...

Page 23: ...er l affichage de la temp rature entre degr s Celsius et degr s Fahrenheit 16 Bouton RCC pour activer ou d sactiver le r cepteur DCF 17 Compartiment de la batterie de secours 18 Entr e de l adaptateur...

Page 24: ...es de mesure 11 Bouton RESET r initialiser l unit ext rieure en cas d erreur ven tuelle 12 Compartiment piles 13 Vis de fixation pour installation sur poteau 2 3 Pluviom tre 1 Collecteur de pluie 2 P...

Page 25: ...l unit ext rieure Comme les piles alcalines normales ne fonctionnent pas ou ne fonctionnent pas bien des temp ratures inf rieures ou gales 0 C l utilisation de piles alcalines standard dans l unit ex...

Page 26: ...e utilisez le niveau bulle int gr au dessus de l unit ext rieure Pour pouvoir indiquer la direction d o vient le vent l unit ext rieure doit tre orient e vers le nord Pour cela voir l indication N en...

Page 27: ...z 0 et appuyez bri vement sur le bouton 10 Utilisez pour r gler la langue pour afficher les jours vous pouvez choisir parmi EN Anglais FR Fran ais DE Allemand ES Espagnol ou IT Italien appuyez bri vem...

Page 28: ...eur 2 Indication batterie faible dans l unit ext rieure 3 Indication de l intensit du signal de l unit ext rieure 4 Temp rature ext rieure 5 Humidit relative ext rieure 4 4 Pr visions m t orologiques...

Page 29: ...ge de la pression de l air relative dans le cas o vous utilisez la station m t o quelque part plus en hauteur que le niveau de la mer ajout 6 Au Benelux on utilise la notation hectopascal Auparavant l...

Page 30: ...secondes 2 Utilisez pour s lectionner l unit souhait e 3 Appuyez bri vement sur le bouton 4 8 Fra cheur du vent et temp rature de ros e 1 indication si la temp rature affich e est dans Feels like Win...

Page 31: ...e d affichage Utilisez le commutateur HI LO AUTO situ l arri re de l unit int rieure pour r gler l clairage de l affi chage AUTO l clairage de l affichage suit l clairage ambiant lorsque la lumi re am...

Page 32: ...ter Vous pouvez arr ter le son d alerte en appuyant bri vement sur le bouton ALARM SNOOZE La valeur de mesure concern e cesse automatiquement de clignoter lors qu elle revient dans les limites d finie...

Page 33: ...recte hPa inHg ou mmHg est utilis e en appuyant bri vement et de mani re r p t e sur le bouton 4 Appuyez et restez appuy sur le bouton pendant environ 2 secondes jusqu ce que ABS ou REL commence clign...

Page 34: ...euvent causer des interf rences cause des communications sans fil TV PC micro ondes Lorsque cela ne r sout pas les probl mes veuillez r initialiser l unit int rieure et l unit ext rieure et signal de...

Page 35: ...1 8 F Affichage m moire historique des 24 derni res heures MIN MAX temp rature avec heure et date Temp rature ext rieure unit s de mesure C ou F Gamme d affichage 40 C 80 C 40 F 176 F LO 40 C Hi 80 C...

Page 36: ...ion 0 1mph ou 0 1knot ou 0 1m s pr cision 5m s 0 5m s 5m s 6 Unit s d affichage moyenne rafale Affichage m moire historique des 24 derni res heures MIN MAX temp rature avec heure et date Direction du...

Page 37: ...37...

Page 38: ...hlie enden Bewertung des Importeurs VORGEHENSWEISE Wenn Sie Sch den bemerken schlagen Sie zun chst in der Bedienungsanleitung nach Wenn Sie in der Anleitung keine zufriedenstellende Antwort finden wen...

Page 39: ...4 7 Wind Richtung Geschwindigkeit 48 4 8 Gef hlte K lte und Taupunkttemperatur 48 4 8 Mondphase 49 4 9 Maximaler Minimaler Speicher 49 4 10 Displaybeleuchtung 49 4 11 Empfangsanzeige der Au eneinheit...

Page 40: ...wird auf der n chsten Seite beschrie ben 3 HISTORY Taste zeigt die Daten der letzten 24 Stunden 4 Niederschlagstaste zur Anzeige der verschiedenen Niederschlagspa rameter 5 Barometer Taste zur Anzeige...

Page 41: ...halten der Temperaturanzeige von Grad Celsius auf Grad Fahrenheit 16 RCC Taste DCF Empf nger aktivieren oder deaktivieren 17 Batteriefach f r die Sicherungsbatterie 18 Netzteileingang Mikro USB Stecke...

Page 42: ...rtragung der Messdaten 11 RESET Taste f r den Reset der Au eneinheit bei einem m gli chen Fehler 12 Batteriefach 13 Befestigungsschrauben zur Montage an einer Stange 2 3 Regenmesser 1 Regensammler 2 K...

Page 43: ...Sie ihn fest Batterien sind nicht im Lieferumfang enthalten Hinweise zu den Batterien f r die Au eneinheit Da normale Alkalibatterien bei Temperaturen um oder unter 0 C nicht oder nur unzureichend fun...

Page 44: ...sein Verwenden Sie dazu die integrierte Wasserwaage oben auf der Au eneinheit Um anzeigen zu k nnen aus welcher Richtung der Wind weht muss die Au eneinheit nach Norden ausgerichtet sein Siehe hierf...

Page 45: ...Sie die Sprache ein in der die Tage angezeigt werden Sie k nnen w hlen aus EN Englisch FR Franz sisch DE Deutsch ES Spanisch oder IT Italienisch dr cken Sie kurz die Taste 11 Mit bestimmen Sie ob die...

Page 46: ...enanzeige 2 Anzeige f r schwache Batterie in der Au eneinheit 3 Signalst rkeanzeige der Au eneinheit 4 Au entemperatur 5 Relative Luftfeuchtigkeit im Au enbereich 4 4 Wettervorhersage Hinweise Eine au...

Page 47: ...Sie die Wetterstation irgendwo weit ber dem Meeresspiegel verwenden Anhang 6 In den Benelux wird die Bezeichnung Hektopascal verwendet Zuvor wurde der Luftdruck manchmal auch in bar ausgedr ckt 1 mbar...

Page 48: ...folgenderma en einstellen 1 Halten Sie die Taste f r 2 Sekunden gedr ckt 2 mit w hlen Sie die gew nschte Einheit aus 3 Dr cken Sie kurz die Taste 4 8 Gef hlte K lte und Taupunkttemperatur 1 Angabe ob...

Page 49: ...den Schalter HI LO AUTO an der R ckseite der Inneneinheit um die Displaybeleuchtung einzustellen AUTO Die Displaybeleuchtung folgt dem Umgebungslicht Bei schwachem Umgebungslicht verringert sich auch...

Page 50: ...d der betreffende Wert zu blinken beginnt Sie k nnen den Warnton stoppen oder kurz die ALARM SNOOZE Taste dr cken Der betreffende Messwert h rt automatisch auf zu blinken wenn er innerhalb des eingest...

Page 51: ...Bezeichnung hPa inHg oder mmHg verwenden indem Sie kurz und wiederholt die Taste dr cken 4 halten Sie die Taste f r ca 2 Sekunden gedr ckt bis ABS oder REL anf ngt zu blinken 5 Mit stellen Sie sicher...

Page 52: ...ren Elektroger ten steht die wegen drahtloser Kommunikation Interferenzen verursachen k nnen TVs PCs Mikrowellen Wenn die Probleme weiterhin bestehen stellen Sie Innen und Au en einheit bitte zur ck u...

Page 53: ...eige Historie der letzten 24 Stunden MIN MAX Temperatur mit Uhrzeit und Datum Au entemperatur Ma einheiten C oder F Anzeigebereich 40 C bis 80 C 40 F bis 176 F LO bei 40 C Hi bei 80 C effektive Reichw...

Page 54: ...s 180km h 97knots Aufl sung 0 1mph oder 0 1knot oder 0 1m s Genauigkeit 5m s 0 5m s 5m s 6 Displayeinheiten Durchschnitt B e Speicheranzeige Historie der letzten 24 Stunden MIN MAX Temperatur mit Uhr...

Page 55: ...caused by material and workmanship errors All this subjected to the final assessment of the importer HOW TO HANDLE If you notice any defect first refer to the user s manual If the manual provides no...

Page 56: ...4 4 7 Wind direction speed 65 4 8 Wind chill and dew temperature 65 4 8 Moon phase 66 4 9 Maximum Minimum memory 66 4 10 Display lighting 66 4 11 Outdoor unit reception indication 66 5 MAX MIN ALERT 5...

Page 57: ...thing shown in the display is described on the next page 3 HISTORY button shows the data of the past 24 hours 4 Rain button for displaying the various rain parameters 5 Barometer button for displaying...

Page 58: ...rature display between degrees Celsius and degrees Fahrenheit 16 RCC button to enable or disable the DCF receiver 17 Battery compartment for the backup battery 18 Power adaptor input micro USB plug 19...

Page 59: ...smitting the measurement data 11 RESET button to reset the outdoor unit in case of a possible error 12 Battery compartment 13 Fastening screws for installation on a pole 2 3 Rain meter 1 Rain collecto...

Page 60: ...s for the outdoor unit Because normal alkaline batteries do not perform or do not perform well at temperatures around or below 0 C the use of standard alkaline batteries in the outdoor unit is not rec...

Page 61: ...e built in spirit level on top of the outdoor unit To be able to indicate from which direction the wind is coming from the outdoor unit must be oriented towards the north See the indication N on top o...

Page 62: ...nguage for displaying the days you may choose from EN English FR French DE German ES Spanish or IT Italian briefly press the button 11 Use to determine whether the clock must automatically switch to d...

Page 63: ...mperature and humidity 1 outdoor indication 2 weak battery indication in the outdoor unit 3 Signal strength indication of the outdoor unit 4 Outdoor temperature 5 Relative outdoor humidity 4 4 Weather...

Page 64: ...justing the relative air pressure display in case you re using the weather station somewhere a lot higher than sea level add 6 In the Benelux one uses the hectopascal notation Before the air pressure...

Page 65: ...d the button for 2 seconds 2 use to select the desired unit 3 briefly press the button 4 8 Wind chill and dew temperature 1 Indication of whether this displayed temperature is the Feels like the Wind...

Page 66: ...HI LO AUTO switch at the rear of the indoor unit to set the display lighting AUTO the display lighting follows the ambient light at low ambient light the display lighting also decreas es at strong amb...

Page 67: ...M SNOOZE button The concerned measurement value automatically stops flashing when it returns to within the set limit or as soon as you adjust the limit or switch off the alert function for this measur...

Page 68: ...nHg or mmHg is used by briefly and repeatedly pressing the button 4 Press and hold the button for approx 2 seconds until ABS absolute or REL relative starts flash ing 5 Use to ensure REL relative is f...

Page 69: ...lec tronic devices that may cause interference because of wireless communication TVs PCs microwaves When this doesn t resolve the problems please reset both the indoor and outdoor unit and reception s...

Page 70: ...to 122 F resolution 0 1 C or 0 1 F accuracy 0 C or 40 C 2 C 32 F or 104 F 3 6 F 0 40 C 1 C 32 104 F 1 8 F memory display history of the past 24 hours MIN MAX temperature with time and date Outdoor te...

Page 71: ...MAX air pressure with time and date Wind speed units of measurement mph m s km h knots display range 0 112mph 50m s 180km h 97knots resolution 0 1mph or 0 1knot or 0 1m s accuracy 5m s 0 5m s 5m s 6...

Page 72: ...ice Help Service Help WWW ALECTO NL SERVICE ALECTO NL Hesdo Australi laan 1 5232 BB s Hertogenbosch The Netherlands WWW ALECTO NL SERVICE ALECTO NL Hesdo Australi laan 1 5232 BB s Hertogenbosch The Ne...

Reviews: