INSTALLATION:
1. Install the mounting plate on a suitable spot
2. Use the included plugs and screws.
3. Now install the detector onto the mounting place and press the detector
down until correctly fastened.
4. The green LED will now blink 6 times to indicate the device is starting.
After this, the green and yellow LED will blink alternately. This is the
warm-up period. This will take 100 seconds.
5. See the installation manual to register the CO detector to the Alecto
SMART-BRIDGE10 and the Smartlife-App.
USE:
1. Every 30 seconds , the green “POWER” LED will flash to indicate the
detector is working.
2. When the detector emits a short beep tone every minute, you should
replace the batteries as soon as possible. When these warnings start,
the detector will continue to function correctly for at least 7 days.
- The table below shows when the detector will sound the alarm.
CO concentration
NO ALARM
for
ALARM
for
33PPM
120 min.
-
55PPM
60 min.
90 min.
110PPM
10 min.
40 min.
330PPM
-
3 min.
In accordance to the EN50291 standard.
3. When the alarm sounds, it will turn off within 6 seconds after moving
the detector to a space with a CO concentration below 40PPM.
4. The alarm sound can be turned off by pressing the button (<150PPM).
5. Every 30 seconds, the detector will automatically perform an error
check.