INSTALLATION INFORMATION:
Attach the ceiling plate using the included plugs and screws to the
ceiling on a location of choice. Wall mounting is not recommended
for smoke detection. Put the 9V block battery in the smoke detec-
tor. Then put the detector to the ceiling plate and, twist clockwise
to lock it in place. Perform a first test by holding the test key for two
seconds. Also see the paragraph: “Testing”.
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector works if the 9V battery has been placed and
the SA-18 has been mounted to the ceiling. The unit can only be
mounted to the plate if the battery has been installed. The LED
underneath the test button will now flash ± every 45 seconds. Once
smoke is detected, the alarm will sound. Once the smoke disap-
pears, the smoke alarm will stop automatically
Time-out function:
With this function the sensitivity of the alarm is reduced for about
10 minutes. This function can be switched on by pressing the
“TEST/HUSH” button once. The sensitivity of the smoke detector
is automatically reduced and the indicator light will briefly light up ±
every 10 seconds to indicate that the sound is temporarily muted.
The alarm is reactivated after 10 minutes. If there is still smoke,
the alarm sound will be heard again. This function can be used
repeatedly.
Test:
Hold the test key for at least 2 seconds. The operation is still cor-
rect if you hear 2 or three signal tones. Check the smoke detectors
weekly. In alarm status the smoke detector will generate about
85dB(A). Do not use candles, open fire or cigarettes to test the
smoke detector.
ATTENTION:
•
If the cause of an alarm is unclear, assume it’s caused by
fire. Immediately evacuate the building.
•
Keep the smoke detectors out of range of children.
•
Protect against dust during rennovations. Without protec-
tion the smoke detectors will lose their functionality.