ALDI WLBCF310 User Manual Download Page 1

SUBMERSIBLE 

WATER PUMP

User 

Manual

Product

Info

www.powertoolsupport.com

Summary of Contents for WLBCF310

Page 1: ...SUBMERSIBLE WATER PUMP User Manual Product Info www powertoolsupport com ...

Page 2: ... website or contact details for example Advantage Your are not required to manually enter a website address or contact details How it works To scan the QR code all you need is a smartphone with QR codes reader software and an Internet connection This type of software can be downloaded for free from your smartphone s app store Try it out now Just scan the QR code with your smartphone and find out m...

Page 3: ...ge of operation of the SubmersibleWater Pump 10 Setup Assembly Preparation for Operation 10 Installing the L shape elbow Connector Adaptor 11 Installing the Adaptor 12 Setting up the Submersible Pump for use 13 Float Switch 14 Priming Procedure 15 Operation 16 Maintenance Cleaning 18 Warranty Environmental Protection What your 3 year warranty means Service Support Accessories 19 Troubleshooting 20...

Page 4: ...our Gardenline Submersible Water Pump When you open your packaging first remove all items and check there are no parts damaged or missing If you find anything wrong do not operate the product until the parts have been replaced or the fault has been rectified Failure to do so could result in serious personal injury Contents of carton 1 x Submersible Pump 1 x L shape Elbow Connector 1 x Adaptor 1 x ...

Page 5: ...roof If the supply cord is damaged it must be replaced by an electrician or a power tool repairer to avoid a hazard The water Pump has a built in thermal protection overload switch The water Pump stops if an over load occurs The motor restarts automatically after it has cooled down Using an Extension Lead Always use an approved extension lead suitable for the power input of this product Before use...

Page 6: ...the plug in any way Do not use any adapter plugs with earthed grounded Pumps Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not abuse the cord Never use the cord for carrying pulling o...

Page 7: ...nnect the plug from the power source before making any adjustments changing accessories or storing Pumps Such preventive safety measures reduce the risk of starting the Pump accidentally b Maintain Pumps Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the Pumps operation If damaged have the Pump repaired before use Many accidents are caus...

Page 8: ...r serious injury WARNING This product is not suitable for use with drinking potable water This appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be superv...

Page 9: ...if an overload occurs The motor restarts automatically after it has cooled down The Pump must not be used in situations where people are in the water Never work or perform maintenance on the Pump without first making sure it has been disconnected from the mains power Pollution of the liquid could occur due to leakage of lubricants Important Avoid inserting hands into the mouth of the Pump if it is...

Page 10: ...800 909 909 MODEL WLBCF310 08 2015 49290 toll free 8 Parts List 1 Float switch cable 2 Float switch cable holder 3 Float switch 4 Carry handle 5 Power cable plug 6 Base and base cover 7 Outlet 8 L shape elbow connector 9 Adaptor 10 Priming vent 11 Base feet x4 12 Inlet same on opposite side 13 Impellor 1 4 8 7 6 9 5 2 12 11 12 13 10 3 ...

Page 11: ...lar applications Note Do not use the Pump in applications in which people or animals are present in the water during operation It is prohibited to operate the equipment if a person or animal is in the danger area This submersible Pump is suitable in the following applications Water removal from rainwater tanks with access from the top of the tank or water line Irrigation and draining out flooded a...

Page 12: ...e float switch is Short float cable setting 350mm 200 mm of water Long Float cable setting 500mm 70 mm of water Setup Assembly Preparation for Operation WARNING Ensure the submersible Pump is disconnected from the mains power supply before undertaking the following assembly preparation WARNING Do NOT put your hands or other body parts into the water when the Pump is in operation and connected to t...

Page 13: ...ts 1 2 below in the section Installing the L shape elbow connector It is recommended to only use this supplied L shape elbow connector on the outlet of the Pump 1 Screw on the L shape elbow connector 8 to the Pump outlet 7 in a clockwise direction until the elbow is tight and FULLY SEATED Pic A 2 To obtain the required outlet direction the elbow can be rotated in an anti clockwise direction up to ...

Page 14: ...For 38 mm internal dia hoses pass the hose over and past sections 1 and 2 of the adaptor push the hose firmly and fully onto section 3 of the adaptor Pic D It is strongly recommended hose clamps are fitted to the hose to retain the hose in place Immersing the end of the hose in hot water prior to attempting to fit the hose may assist in fully fitting the hose on to section 1 or 3 of the adaptor 2 ...

Page 15: ...rge enough to allow the float to float and move freely We recommend a minimum area of 50cm for each side of the submersible Pump Pic G Do not place the submersible Pump into directly onto mud or debris If the Pump is being used in dirty water it is recommended to place the Pump on a clean hard surface in the water such as a concrete slab or block This will avoid the Pump becoming blocked Note The ...

Page 16: ...Pump off when the float is tilted downward at approx 30 Pic H By clipping the float cable into the cable clip Pic I and changing the length the height of the water level and range of the On Off cycle can be altered A minimum of 10cm should be maintained between the float and the clamp Pic J By lengthening the distance between the clip and the float the higher the water level to the Pump On point T...

Page 17: ...ming the Pump where the area to be pumped is already dry to start with or up to 100mm of water This could be a drain pit or a dry pond or an area prone to flooding Install the Pump in the position required on the dry mount set the float switch connect the outlet plumbing and connect the mains power cable In this condition there is NO NEED to prime the Pump As the water enters the Pump area and ris...

Page 18: ...n be operated regardless of the water level by lifting the float into a vertical position If retained in this position the Pump will continue to operate without turning off as the water level drops In this condition the Pump must be manually turned off at the power point when the minimum water level is achieved being approx 30 50 mm The Pump should not be left running when the minimum water level ...

Page 19: ...e the Pump is immersed in water ensure the Pump is primed as per the priming section of this manual If using in deep water use a rope not included by securing it to the carry handle 4 Place the Pump in the required position for operation Pic M 3 To commence operation insert the power plug into the mains power supply and switch On Pic N If the Pump has been immersed in water and the float is liftin...

Page 20: ...emoved to remove the base and cover Clear the blockage from the impeller Then replace the cover and base and the 3 assembly screws NOTE DO NOT separate the lower and upper housing of the Pump Before using the water Pump always inspect it visually Do not use the Pump if it is cracked and or damaged If the water Pump is damaged con tact customer service Make sure that electrical connections are prot...

Page 21: ... into the manufacture of this product and it should therefore provide you with years of good service when used properly In the event of product failure within its intended use over the course of the first 3 years after the date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event of such an occur rence or if you require any i...

Page 22: ...age in the discharge lines Prime the Pump using the method described on page 15 Turn Pump off at the mains power supply and clean the base of any foreign matter and debris Remove the obstructions Reduce the height of the discharge point Note the lower the discharge point the faster the flow rate Ensure the discharge lines are the correct length and all assembly instructions are adhered to Pump wil...

Page 23: ...afety and EMC Compliance Read these instructions for use carefully Warning Voltage 220 240V 50Hz Input Watts 750W Max Flow Rate 14 000 L H Max Immersion depth 7m Max Head 8m Phase Single Temperature Rating Fluid temperatures up to 35 C Maximum ambient temperature 40 C Max Foreign particle size Ø 20mm Protection type IPX8 Cord length 10m Weight 5 2kg Recycling Environmental protection Recycle unwan...

Page 24: ...t our exclusive brand products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China Gardenline is a registered trademar...

Reviews: