Cast Iron Cable Weight

Control and Pump Switches

Summary of Contents for 7039

Page 1: ...USER GUIDE PART NUMBER 7039 Cast Iron Cable Weight Control and Pump Switches...

Page 2: ...a 8 Testing 8 General Operation 9 Narrow Angle Control or Pump Switch Information 9 Medium Angle Control Switch Information 10 Medium Angle Pump Switch Information 10 Wide Angle Control or Pump Switch...

Page 3: ...ust be installed by qualified personnel familiar with all applicable local electrical and mechanical codes Refer to the National Electrical Code NFPA 70 Failure to properly install and test this produ...

Page 4: ...uct Included 1 Cast Iron Cable Weight The cast iron cable weight is used as a pivot point for the desired activation level of the float switch 2 Screws Secures the cast iron cable weight to the float...

Page 5: ...n 2 Screw Holes Two screw holes are located on the front outside portion of the cable weight 3 Threaded Screw Holes Two threaded screw holes are located on the inside back portion of the cable weight...

Page 6: ...l place float switch cable in the cable slot on the bottom half of the cable weight while the top half is removed and tether float switch to the appropriate length Refer to the instructions that came...

Page 7: ...he cable weight over the float switch cable and align the screw holes to the bottom half of the cable weight 3A Tighten the two screws so both halves of the cable weight are snug against the cable 3B...

Page 8: ...sing a mounted float bracket or per local codes STEP 2 WIRING Wire the float switch per manufacturer s instructions Testing STEP 1 TESTING THE ACTIVATION LEVEL Check the installation of the float swit...

Page 9: ...oat switches Note Other brands of float switches may have different total operating angles or activation deactivation levels above below horizontal Refer to the instructions that came with the float s...

Page 10: ...wn empty applications Normally Closed Low Level Alarms or Pump Up fill applications Medium Angle Control Switch Information normally open example normally open example 50 total operating angle Normall...

Page 11: ...ms or Pump Down empty applications Normally Closed Low Level Alarms or Pump Up fill applications normally open example Multiple float switches with cable weights are typically used for control applica...

Page 12: ...he bottom half of the cable weight Align the screws holes on the top half of the cable weight with threaded screw holes on the bottom half of the cable weight securely fasten screws Float switch cable...

Page 13: ...R GUIDE Specifications Cable Weight Material Screws Material Cable Slot Operating Temperature Diameter Height Weight Zinc plated cast iron Stainless steel 18 AWG to 14 AWG type cable sizes diameter 0...