![Alcatel 7750 SR-12 Installation Manual Download Page 71](http://html1.mh-extra.com/html/alcatel/7750-sr-12/7750-sr-12_installation-manual_2891366071.webp)
Installing Power Supplies
7750 SR-12
Page 69
DC-I
NPUT
P
OWER
W
IRING
P
REPARING
THE
P
OWER
C
ABLE
Connect the VCD and RTN studs on the DC terminal block with power cables terminated with
0.250-20 UNC lugs (
). The other unterminated end of the power cables
must be prepared according to your local safety codes. The length of the power cable depends on
the location of the router and proximity to the power source.
Figure 17: DC Terminal Block Stud Dimensions and Spacing
Figure 18: DC Terminal Block Lug
Warning:
• Ensure that all power is OFF from the DC circuit. Locate the circuit breaker on the panel board
that services the DC circuit. Switch the circuit breaker to the OFF position.
• When wiring the unit, the ground connection must always be made first and disconnected last.
• The proper wiring sequence is ground/negative to ground/negative and positive/return to
positive/return.
• Use a #6 American wire gauge (AWG) for the -48 and RTN power connections.
SR12032
3.965 IN.
0.850 IN.
0.740 IN.
0.600 IN.
1.300 IN.
0.750 IN.
1
0.750"
0.250
2 Holes
All measurements in inches.
SR12030
Summary of Contents for 7750 SR-12
Page 1: ...7750 SR 12 INSTALLATION GUIDE Document Part Number 93 0019 01 December 2003 ...
Page 6: ...Page 4 7750 SR 12 Table of Contents ...
Page 14: ...Page 12 7750 SR 12 ...
Page 84: ...Monitoring AC Power Page 82 7750 SR 12 ...
Page 100: ...Establishing Router Connections Page 98 7750 SR 12 ...
Page 150: ...Impeller Trays Page 148 7750 SR 12 ...