Manual switching tests
Ring setup and testing: integration procedures
6 - 1 4
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
Manual switching tests
Description
This test will initiate switching commands from the CIT and verify proper switching and
LED indications.
Important!
An STS-1 cross-connect is required in order to perform manual
switching.
Manual switching test procedure
........................................................................................................................................................................................................................
1
Enter an STS-1 add/drop cross-connection between an equipped Function Unit and the
Main OLIU. Select Configuration -> Cross-Connections... and use the Cross-Connection
Wizard to enter an add/drop cross-connection.
........................................................................................................................................................................................................................
2
Select Fault -> Protection Switch...
........................................................................................................................................................................................................................
3
Under Path Protection choose Path m-1-1 and click Select.
........................................................................................................................................................................................................................
4
Note the Active Path (m1 or m2).
........................................................................................................................................................................................................................
5
Choose Switch Type: Manual.
........................................................................................................................................................................................................................
6
Click Apply.
........................................................................................................................................................................................................................
7
Verify that the Active Path: has changed (m1 to m2 or m2 to m1).
........................................................................................................................................................................................................................
8
to verify a switch back to the original ring.