Optical transmission test (OC-192, OC-48, OC-12)
Ring setup and testing: integration procedures
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
6 - 1 1
............................................................................................................................................................................................................................................................
Optical transmission test (OC-192, OC-48, OC-12)
Overview
The following test verifies error-free transmission between nodes.
Transmission test procedure
........................................................................................................................................................................................................................
1
At the test location, select Performance -> View PM Reports -> OCn Section...
........................................................................................................................................................................................................................
2
Choose CP main-1, Port 1
........................................................................................................................................................................................................................
3
Click Select.
........................................................................................................................................................................................................................
4
Select Time Period: 15-Min, Monitored Date: Current Date and Monitor Level: 0 UP.
........................................................................................................................................................................................................................
5
Click Select All to move all Available Parameters to the Selected Parameters column.
........................................................................................................................................................................................................................
6
Click Apply.
Result:
The Response Window indicates no transmission errors.
........................................................................................................................................................................................................................
7
substituting CP main-2 in
.
........................................................................................................................................................................................................................
8
for all 1665 DMX shelves at the test location.
........................................................................................................................................................................................................................
9
and
for each node in the ring.
........................................................................................................................................................................................................................
10
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S