Alcatel-Lucent AOS-W 3.4 Quick Start Manual Download Page 3

AOS-W 3.4

| Quick Start Guide

3

    

z

Install licenses for AOS-W software modules

z

Configure internal and guest WLANs

Running the Setup Wizard

The default IP address of the switch is 172.16.0.254. When you connect a PC or workstation to a line port on 
the switch, you can connect to this IP address through a Web browser to run the Setup Wizard.

You can use any PC or workstation on which you can run a Web browser. The system must either be 
configured to obtain its IP address via DHCP or configured to have a static IP address on the 172.16.0.0/24 
subnetwork.

To run the Setup Wizard:

1. Make sure that the switch is not connected to any device on your network.

2. Boot up the Alcatel-Lucent switch.

3. Connect your PC or workstation to a line port on the switch.

4. On your PC or workstation, open a Web browser and connect to https://172.16.0.254.

5. The switch contains a default server certificate. At the Security Alert, click 

Yes

 to proceed with the 

Setup Wizard.

6. Enter the information described in 

Table 1

.

7. Click 

Continue

 to install software licenses on the switch.

Proceed to 

"Connect the Controller to the Wired Network" on page 4

Serial Port Connection

The serial port is located on the front panel of the switch. When you connect a terminal or PC/workstation 
running a terminal emulation program to the serial port on the switch, you enter the Initial Setup dialog.

To run the Initial Setup dialog from a serial connection:

1. Configure your terminal or terminal emulation program to use the following communication settings:

2. Connect your terminal or PC/workstation to the serial port on the switch using an RS-232 serial cable. 

All accessory kits shipped with Alcatel-Lucent controllers contain an RJ-45 cable and DB-9 to RJ-45 
adapter for this purpose. You may need to provide a USB adapter to connect the serial cable to your PC.

N O T E

A digital certificate is a way to validate a device on the network. The default certificate installed in the switch does 

not guarantee security in production networks. Alcatel-Lucent strongly recommends that you replace the default 

certificate with a custom certificate issued for your site or domain by a trusted Certificate Authority. See the 

AOS-

W 3.4 User Guide

 for more information about certificates.

N O T E

The serial port connection allows you to configure the basic configuration required to connect the switch to the 

network. The browser-based Setup Wizard allows you to also install software licenses and configure internal and 

guest WLANs (see “Run the Setup Wizard” on page 1). If you use the Initial Setup dialog to configure the switch, 

the Setup Wizard will not be available unless you reset the switch to its factory default configuration.

Table 2  

Terminal Communication Settings

Baud Rate

Data Bits

Parity

Stop Bits

Flow Control

9600

8

None

1

None

Summary of Contents for AOS-W 3.4

Page 1: ...ge 4 4 Ensure that the APs when installed and powered on will be able to locate and connect to the switch For more information see Ensure APs Can Connect to the Controller on page 4 5 Define the mesh cluster profile mesh radio profile and provision the AP as a mesh portal or mesh point when deploying APs in a mesh networking environment For more information see Provision APs for Mesh on page 5 6 C...

Page 2: ...ssignment can disrupt wireless transmissions Most countries impose penalties and sanctions for operators of wireless networks with devices set to improper country codes admin Password Password of up to 32 characters for the admin user to log in to the switch Enable Mode Password Password of up to 15 characters for the admin user to access the Enable mode in the CLI Date and Time You can either man...

Page 3: ...e serial port on the switch you enter the Initial Setup dialog To run the Initial Setup dialog from a serial connection 1 Configure your terminal or terminal emulation program to use the following communication settings 2 Connect your terminal or PC workstation to the serial port on the switch using an RS 232 serial cable All accessory kits shipped with Alcatel Lucent controllers contain an RJ 45 ...

Page 4: ...CP to provide IP addresses for APs the DHCP server can be an existing network server or an Alcatel Lucent switch configured as a DHCP server If an AP is on the same subnetwork as the master switch you can configure the switch as a DHCP server to assign an IP address to the AP The switch must be the only DHCP server for this subnetwork Using the WebUI to Enable DHCP Server Capability on the Control...

Page 5: ...before configuring an AP to operate as a mesh node An AP configured for mesh is also known as a mesh node z Provision one of the following mesh roles on the AP Mesh portal The gateway between the wireless mesh network and the enterprise wired LAN Mesh point APs that can provide traditional Alcatel Lucent WLAN services such as client connectivity intrusion detection system IDS capabilities user rol...

Page 6: ...etwork and powered up it attempts to locate the switch using ADP On the switch you can view the APs that have connected to the switch in the WebUI Navigate to the Configuration Wireless AP Installation page Figure 1 APs Connected to Controller After you have installed a basic Alcatel Lucent user centric network the Alcatel Lucent AP advertises the default aruba ap SSID Wireless users can connect t...

Page 7: ...e by all individuals or corporations to terminate Cisco or Nortel VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies in full Alcatel Lucent from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of Cisco Systems or Nortel Networks Table 3 Alcatel Lucent Contacts...