Wiring and Connecting DC Power
78
7705 SAR-A Chassis Installation Guide
Wiring and Connecting DC Power
Wiring and Connecting the DC Inputs
The 7705 SAR-A has a dual-feed, wire-to-board, pluggable terminal block attached to the
front of the chassis. The terminals are the DC power feed points for source voltage from the
DC circuit.
For redundant power configurations, you must use both DC power feeds (one for each pair of
power terminals).
To connect the power cables to the terminal block, remove 0.35 in. (9 mm) of outer shielding
from each power cable at the router end, as shown in
.
identifies the key
items in the figure.
Figure 17: DC Power Cable
Note:
•
Ensure that you read and observe all the dangers and warnings described in the
chapter before wiring and connecting power to the 7705 SAR-A.
•
The 7705 SAR-A requires a minimum of one DC power source to operate, but using two
DC power sources is recommended for redundancy.
•
The 7705 SAR-A is suitable for both DC-I and DC-C power configurations.
•
All bare conductors must be coated with an appropriate antioxidant compound before
crimp connections are made. All unplated connectors, braided straps, and bus bars
must be brought to a bright finish and then coated with an antioxidant before connecting
them.
Table 17: DC Power Cable Descriptions
Key
Description
1
Copper wire
2
1
23318
Summary of Contents for 7705 SAR-A
Page 23: ...Mandatory Regulations 7705 SAR A Chassis Installation Guide 23 Figure 3 Earth ground 9718 ...
Page 66: ...Installation Site Assessment 66 7705 SAR A Chassis Installation Guide ...
Page 76: ...Chassis Ground Wiring 76 7705 SAR A Chassis Installation Guide ...
Page 82: ...Wiring and Connecting DC Power 82 7705 SAR A Chassis Installation Guide ...
Page 132: ...7705 SAR A Ports 132 7705 SAR A Chassis Installation Guide ...
Page 154: ... 2015 Alcatel Lucent All rights reserved 3HE 10141 AAAB TQZZA Edition 01 ...