General Requirements
18
7705 SAR-A Chassis Installation Guide
General Requirements
The sections that follow outline the mandatory regulations that govern the installation and
operation of the 7705 SAR-A. The information in this section also describes instructions and
information related to overall conformance with the mandatory regulations. You must adhere
to these instructions so that your system meets regulatory requirements.
Anti-static Measures
shows the ESD awareness label used on Alcatel-Lucent products to alert personnel
to the presence of ESD-sensitive devices in the product. The necessary ESD precautions must
be taken whenever this symbol is present on the product.
Figure 1: ESD Awareness Label
This guide uses the following icon and associated text to provide special information relating
to ESD-sensitive activities or situations.
Warning:
•
There are no user-serviceable parts in this unit. Refer servicing to qualified personnel.
•
The 7705 SAR-A should be connected to a DC branch circuit with a minimum 5 A and
maximum 10 A circuit breaker or fuse that meets the requirements for branch circuit
protection.
•
A suitable disconnect device, such as a circuit breaker or switch, must be provided in
the DC branch circuit and must be used to disconnect power to the system during
servicing.
17658
Summary of Contents for 7705 SAR-A
Page 23: ...Mandatory Regulations 7705 SAR A Chassis Installation Guide 23 Figure 3 Earth ground 9718 ...
Page 66: ...Installation Site Assessment 66 7705 SAR A Chassis Installation Guide ...
Page 76: ...Chassis Ground Wiring 76 7705 SAR A Chassis Installation Guide ...
Page 82: ...Wiring and Connecting DC Power 82 7705 SAR A Chassis Installation Guide ...
Page 132: ...7705 SAR A Ports 132 7705 SAR A Chassis Installation Guide ...
Page 154: ... 2015 Alcatel Lucent All rights reserved 3HE 10141 AAAB TQZZA Edition 01 ...