2 Mbit/s output timing mode change
...................................................................................................................................................................................................................................
Alarm identifier
P12OTMcSW
Information
The quality level of the clock used for retiming the 2 Mbit/s output signal has
no longer sufficient quality.
Alarm category
Transmission
ASAP
pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
–
Cause
The quality of the system clock is not sufficient for re-timing purposes.
Actions
Restore the original timing source, or reconfigure the most reliable timing
source to improve the quality of the system clock, or change the threshold
quality alarm level.
Note(s)
The consequent action of this alarm is user provisionable (including but not
limited to switching from the re-timed to the self-timed mode).