Wrong Pluggable Module present
...................................................................................................................................................................................................................................
Alarm identifier
PMcWUP
Information
A wrong pluggable module is present in an assigned pluggable module socket,
or the present pluggable module cannot be identified.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
The red fault LED associated to the failed pluggable module is lit.
Cause
Wrong pluggable module inserted, or the inserted pluggable module is
defective.
Actions
Insert a pluggable module of the correct type, or change the provisioning.
If a pluggable module of the correct type is already present in the respective
socket when the alarm is reported, then the pluggable module is defective and
has to be replaced.