VC-4 Path trace identifier mismatch
...................................................................................................................................................................................................................................
Alarm identifier
VC4cTIM
Information
The received path trace identifier, used to verify the continued connection to
the intended transmitter, does not match the provisioned value.
Alarm category
Transmission
ASAP
sdhHOPath
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
In the reporting Network Element:
•
In the upstream direction, “VC-4 Remote Defect Indicator” is activated.
•
In the downstream direction, the alarm indication signal is inserted into the
next function.
Cause
Wrong routing somewhere in the network due to:
•
Wrong connected line cables.
•
Wrong Expected Trace Identifier filled in via the management system for
the network element that reported the alarm.
Actions
Determine in which network element(s) the line cables are wrongly connected
by interpreting the received VC-4 path trace identifiers.
Check correctness of expected path trace identifier.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-295