Technote 3: Setting up PC-525 Channel Processors 

PC-Series are fully agile Channel processors for the VHF/UHF band. The channel processor 
has  a  built-in  double  FOS  filter,  so  that  it  is  possible  to  program  the  output  with  adjacent 
channels. 
 

 

 

IMPORTANT:

  Layout  of  the  modules  must  be  as  shown  above.  Power  Supply  (FA-310/312) 

must  be  located  on  the  far  left  hand  side  and  launch  amplifier  (PA-720)  must  be  the  next 
module in the chain.  Please look at the above picture. 
 

AIM  PROGRAMMER  TO  IR  SENSOR  LOCATED  ON  EACH  PROCESSOR 
WHEN PROGRAMMING 

 

Programming of Modules 

 
Ensure the following prior to programming: 
 

  It is necessary to connect all the modules to the support frame SP-226 (code 9120130) 

for the system to function.  
 

  It is also recommended that you make the earth connection to the building using a cable 

with a section of at least 4 mm. 

 

  Ensure that you have the Alcad programmer PS-003 with 

firmware version 4.7

 or later. 

 

  Power  supply/Control  cable  must  be  plugged  into  each  module. 

DO  NOT  ADD  OR 

REMOVE 

modules without disconnecting mains supply power from wall outlet.  Always 

disconnect  the  equipment,  and  then  reconnect  it  to  the  mains  supply  so  that  the 
amplifier recognises the new module. Failure to do so can cause equipment to fail. 
 

Launch Amplifier 

Power Supply 

IR Sensors 