Remote control

Commissioning

• 

Remove the film (17); the remote control is ready to operate.

Changing batteries 

• 

Unhook and pull out the battery compartment on the back cover.

• 

Take out and dispose of the empty batteries.

• 

Insert new batteries in the battery compartment. Make sure to insert them with 

correct polarity.

• 

Insert the battery compartment and snap it into place. The remote control is 

ready to operate.

Appendix

Technical data

Music Centre
Power supply

Rated voltage:  ..........................................................................................AC 230 V ~

Mains frequency  ...........................................................................................50/60 Hz

Connection  ........................................................................................Screw terminals

Max. clampable cable cross-section .............................................................. 2.5 mm²

Protection class  .................................................................................................. IP 20

AUX

Connection  ...................................................................................stereo jack 3.5 mm

Line out

Output impedance line out ............................................................................470 Ohm

Connection  ........................................................................................Screw terminals

Max. clampable cable cross-section .............................................................. 1.5 mm²

Loudspeaker

Rated output  ................................................................................................ 2 x 1.2 W

Loudspeaker impedance  .............................................................................. 4-8 Ohm

Connection  ........................................................................................Screw terminals

Max. clampable cable cross-section .............................................................. 1.5 mm²

Charging socket

Rated voltage  ..................................................................................................DC 5 V

Rated current  ..............................................................................................max. 0.8 A

Connection  .................................................................................................. mini USB

Infrared remote control

Rated voltage  ..................................................................................................DC 3 V

Battery type  ............................................................................................ 1 x CR 2025

Protection class  .................................................................................................. IP 20

Summary of Contents for MC .. 100 .. Series

Page 1: ...Music Centre Art No MC 100 ALBRECHT JUNG GMBH CO KG Volmestrasse 1 58579 Schalksmühle Germany mail info jung de www jung de www jung katalog de GB ...

Page 2: ... burn hazard Batteries may burst or leak Only replace batteries with the same or an equivalent type Remove empty batteries immediately and dispose of them in an environmen tally responsible manner Do not dispose of batteries in household refuse Information about environmentally responsible disposal is available from local refuse disposal authorities Legal requirements state the end consumer is re ...

Page 3: ...input with 3 5 mm stereo jack Integrated stereo amplifier Direct connection of loudspeakers Line out outputs to connect a hi fi or multi room system Volume control directly on device Remote control via infrared remote control Battery loading function for mobile devices via mini USB connection Operation Operation takes place at the music centre via remote control or directly at the MP3 player 8 9 1...

Page 4: ... via the music centre or directly via the player Green LED 7 is off Press changeover switch 9 Green LED 7 lights up AUX input is active Connecting devices to the mini USB interface Mini USB connection for charging batteries of suitable mobile devices Connect the device via the mini USB cable at connection 6 Only one device can be charged at a time The charging function via the docking station 4 ha...

Page 5: ...ore working on the device disconnect the power and cover live parts in the area Connecting and fitting the music centre L N AC 230 V 22 18 19 20 21 23 24 Figure 4 Loudspeaker connection 18 Power supply AC 230 V 19 Loudspeaker connection left 20 Loudspeaker connection right 21 Insulating sleeve 22 Stereo mono changeover switch 23 Line out connection right 24 Line out connection left ...

Page 6: ...n electrical shock Lay the loudspeaker or line out cables in the device box in the additional insulation sleeves Lay the cables for loudspeaker and line out outputs in the device box in insula tion sleeves Connect the insert in accordance with the connection plan Image 4 and 5 Set mono stereo operation via the slide switch 22 i i For operation with one loudspeaker connection left or right mono For...

Page 7: ...data Music Centre Power supply Rated voltage AC 230 V Mains frequency 50 60 Hz Connection Screw terminals Max clampable cable cross section 2 5 mm Protection class IP 20 AUX Connection stereo jack 3 5 mm Line out Output impedance line out 470 Ohm Connection Screw terminals Max clampable cable cross section 1 5 mm Loudspeaker Rated output 2 x 1 2 W Loudspeaker impedance 4 8 Ohm Connection Screw ter...

Page 8: ...ünen Service line 49 0 23 55 80 65 51 Fax 49 0 23 55 80 61 89 mail vki jung de Systems general Service line 49 0 23 55 80 65 55 Fax 49 0 23 55 80 62 55 mail vkm jung de Systems KNX Service line 49 0 23 55 80 65 56 Fax 49 0 23 55 80 62 55 mail vkm jung de The CE mark is a free trade symbol intended solely for the authorities and does not carry any guarantee of properties ALBRECHT JUNG GMBH CO KG Vo...

Reviews: