32
English
5.9. VOX function
Briefl y press the
VOX
button to switch
the VOX function on or off. When the
VOX function is activated, the radio
automatically switches to transmission
as soon as it detects speech. You no
longer need to pick up the microphone
to transmit messages.
The active VOX function is indicated by
the
symbol on the display.
5.9.1. VOX sensitivity
The VOX Level is used to select the volume level above which
an automatic VOX transmission is activated.
Go to the main menu and select
VOX.L
to set sensitivity:
1 = low sensitivity, VOX only reacts to very high volume levels
9 = high sensitivity, VOX already reacts to very low volume
levels
The default value is level 6.
5.9.2. VOX delay
Go to the main menu an select
VOX.T
to select the delay time
with the
UP/DN
keys.
The VOX delay function sets the time after which the automatic
transmission mode is disabled if no speech is detected:
Stufe
1
2
3
4
5
6
7
8
9
Zeit
(Sek)
0,5 1,0 1,5
2,0
2,5 3,0 3,5
4,0 4,5
There are 9 confi gurable delay levels. The default value is level 4.