Albion TCT100 Operating Manual Download Page 4

OPERATING MANUAL AND USER GUIDE

Important Safety Instructions

1.  Read these instructions – All the safety and operating 

instructions should be read before this product is 
operated.

2.  Keep these instructions – The safety and operating 

instructions should be retained for future reference.

3.  Heed all warnings – All warnings on the appliance 

and in the operating instructions should be adhered 
to.

4.  Follow  all  instructions  –  All  operating  and  use 

instructions should be followed.

5.  Do not use this apparatus near water – The appliance 

should  not  be  used  near  water  or  moisture  –  for 
example, in a wet basement or near a swimming pool 
etc.

6.  Clean only with dry cloth.

7.  Do  not  block  any  ventilation  openings.  Install  in 

accordance with the instructions.

8.  Do  not  install  near  any  heat  sources  such  as 

radiators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or 

grounding plug. A polarized plug has two blades with 
one wider than the other. A grounding plug has two 
blades and a third grounding prong. The wide blade 
or the third prong is provided for your safety. If the 
provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10.  Protect  the  power  cord  from  being  walked  on  or 

pinched  particularly  at  the  plugs,  convenience 
receptacles, and at the point where they exit from the 
apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12.  Use  only  with  the  cart,  stand,  tripod,  bracket  or 

table specified by the manufacturer, or sold with the 
apparatus. When a cart or rack is used, use caution 
when  moving  the  cart/  apparatus  combination  to 
avoid injury from tip-over.

13.  Unplug the apparatus during lightning storms or when 

unused for long periods of time.

14.  Refer all servicing to qualified personnel. Servicing is 

required when the apparatus has been damaged in 
any way including: power supply cord or plug damage, 
liquid spillages, objects falling into the unit, exposure 
to rain/moisture or impact damage.

15.  Please keep the unit in a well ventilated environment.

16.  CAUTION: These servicing instructions are for use 

by qualified service personnel only. To reduce the 
risk of electric shock, do not perform any servicing 
other than that contained in the operating instructions 
unless you are qualified to do so.

17.  WARNING: To reduce the risk of fire or electric shock 

do not expose this apparatus to rain, moisture and 
dripping  or  splashing  of  liquids.  Containers  filled 
with liquids such as vases or drinks should never be 
placed on top of or near the unit.

18.  WARNING: The mains plug/appliance coupler is used 

as disconnect device, the disconnect device shall 
remain readily operable.

19.  The lightning flash with arrowhead symbol is to alert 

the user to the presence of non-insulated "dangerous 
voltage" within the product's enclosure that may be 
of sufficient magnitude to constitute a risk of electric 
shock.

 
 

- Warning: To reduce the risk of electric shock, do 
not remove cover (or back) as there are no user-
serviceable parts inside. Refer servicing to qualified 
personnel.

 

1

TCT 50.indd   4

2011-5-5   18:32:01

Summary of Contents for TCT100

Page 1: ...OPERATING MANUAL AND USER GUIDE TCT50 TCT100 www albionamps com TCT 50 indd 1 2011 5 5 18 32 00...

Page 2: ...TCT 50 indd 2 2011 5 5 18 32 00...

Page 3: ...nts Important Safety Instructions 1 Important Warnings 2 Designer s Introduction 3 Outline Specification 3 TCT50 TCT100 Features and Controls 5 Rear Panel 7 Specification 8 TCT 50 indd 3 2011 5 5 18 3...

Page 4: ...cturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart or rack is used use caution when moving the cart apparatus combinati...

Page 5: ...nt you from receiving a fatal electric shock NEVER use your amplifier equipment in a high moisture environment such as rain or allow it to get wet ALWAYS use correct and well maintained cables for all...

Page 6: ...ate switchable channels both featuring the same controls per channel Channel A features the EQ circuit before the gain stages whilst Channel B features the EQ after the gain stages Both channels featu...

Page 7: ...e seamless channel switching In MIX mode a Balance control allows the MIX level to be adjusted higher or lower than the A B volume level enabling the MIX to be used as a Lead boost for instance The TC...

Page 8: ...ese controls set to mid position What is important to remember is that the EQ circuit is connected before the gain circuits on channel A and after the gain circuits on channel B Putting this as simply...

Page 9: ...you want the MIX mode to be for instance as a rhythm mode and therefore quieter than A or B then turn the Balance down below centre position MASTER OUTPUT This volume control is placed between the wh...

Page 10: ...the white rating label fitted to the back panel If in any doubt please check with your supplier It is of utmost importance to use the correct earthed and rated power cord as is supplied with your amp...

Page 11: ...protection treat them with respect and never replace with the wrong value Mains Fuse 120V 60 Hz supply T3 2AL time lag 250V rated 20mm glass fuse Mains Fuse 230V 50 Hz supply T1 6AL time lag 250V rate...

Page 12: ...Court Ermine Business Park Huntingdon Cambs PE29 6XU England www albionamps com The information in this brochure is subject to change without notice All rights reserved 2010 Albion Albion is a member...

Reviews: