background image

OPERATING MANUAL AND USER GUIDE

&

Important Safety Instructions

1.  Read these instructions – All the safety and operating 

instructions  should  be  read  before  this  product  is 
operated.

2.  Keep these instructions – The safety and operating 

instructions should be retained for future reference.

3.  Heed  all  warnings  –  All  warnings  on  the  appliance 

and in the operating instructions should be adhered 
to.

4.  Follow  all  instructions  –  All  operating  and  use 

instructions should be followed.

5.  Do not use this apparatus near water – The appliance 

should  not  be  used  near  water  or  moisture  –  for 
example, in a wet basement or near a swimming pool 
etc.

6.  Clean only with dry cloth.

7.  Do  not  block  any  ventilation  openings.  Install  in 

accordance with the instructions.

8.  Do  not  install  near  any  heat  sources  such  as 

radiators, heat registers, stoves, or other apparatus 

LQFOXGLQJDPSOL¿HUVWKDWSURGXFHKHDW

9.  Do not defeat the safety purpose of the polarized or 

grounding plug. A polarized plug has two blades with 
one wider than the other. A grounding plug has two 
blades and a third grounding prong. The wide blade 
or the third prong is provided for your safety. If the 

SURYLGHGSOXJGRHVQRW¿WLQWR\RXURXWOHWFRQVXOWDQ

electrician for replacement of the obsolete outlet.

10.  Protect  the  power  cord  from  being  walked  on  or 

pinched  par ticularly  at  the  plugs,  convenience 
receptacles, and at the point where they exit from the 
apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12.  Use  only  with  the  cart,  stand,  tripod,  bracket  or 

WDEOHVSHFL¿HGE\WKHPDQXIDFWXUHURUVROGZLWKWKH

apparatus. When a cart or rack is used, use caution 
when  moving  the  cart/  apparatus  combination  to 
avoid injury from tip-over.

13.  Unplug the apparatus during lightning storms or when 

unused for long periods of time.

 5HIHUDOOVHUYLFLQJWRTXDOL¿HGSHUVRQQHO6HUYLFLQJLV

required when the apparatus has been damaged in 
any way including: power supply cord or plug damage, 
liquid spillages, objects falling into the unit, exposure 
to rain/moisture or impact damage.

15.  Please keep the unit in a well ventilated environment.

16.  CAUTION: These servicing instructions are for use 

by  qualified  service  personnel  only.  To  reduce  the 
risk of electric shock, do not perform any servicing 
other than that contained in the operating instructions 

XQOHVV\RXDUHTXDOL¿HGWRGRVR

 :$51,1*7RUHGXFHWKHULVNRI¿UHRUHOHFWULFVKRFN

do  not  expose  this  apparatus  to  rain,  moisture  and 
dripping  or  splashing  of  liquids.  Containers  filled 
with liquids such as vases or drinks should never be 
placed on top of or near the unit.

18.  WARNING: The mains plug/appliance coupler is used 

as  disconnect  device,  the  disconnect  device  shall 
remain readily operable.

 7KHOLJKWQLQJÀDVKZLWKDUURZKHDGV\PEROLVWRDOHUW

the user to the presence of non-insulated "dangerous 
voltage" within the product's enclosure that may be 

RIVXI¿FLHQWPDJQLWXGHWRFRQVWLWXWHDULVNRIHOHFWULF

shock.

 
 

-  Warning:  To  reduce  the  risk  of  electric  shock,  do 

QRW UHPRYH FRYHU RU EDFN DV WKHUH DUH QR XVHU
VHUYLFHDEOHSDUWVLQVLGH5HIHUVHUYLFLQJWRTXDOL¿HG

personnel.

 

1

ABH300H.indd   4

2011-5-5   18:34:05

Summary of Contents for ABH200C

Page 1: ...OPERATING MANUAL AND USER GUIDE ABH200C ABH300H www albionamps com ...

Page 2: ......

Page 3: ...Contents Important Safety Instructions 1 Important Warnings 2 Designer s Introduction 3 2XWOLQH 6SHFL FDWLRQ 3 ABH200C ABH300H Features and Controls 4 Rear Panel 5 6SHFL FDWLRQ 6 ...

Page 4: ...es specified by the manufacturer 12 Use only with the cart stand tripod bracket or WDEOH VSHFL HG E WKH PDQXIDFWXUHU RU VROG ZLWK WKH apparatus When a cart or rack is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug the apparatus during lightning storms or when unused for long periods of time 5HIHU DOO VHUYLFLQJ WR TXDOL HG SHUVRQQHO 6HUYLFLQJ LV ...

Page 5: ...fier It is there to prevent you from receiving a fatal electric shock NEVER use your amplifier equipment in a high PRLVWXUH HQYLURQPHQW VXFK DV UDLQ RU DOORZ LW WR JHW wet 6 XVH FRUUHFW DQG ZHOO PDLQWDLQHG FDEOHV IRU all inter connections whether for power speaker or signal connections If in any doubt get them checked or renew immediately 1 9 5 XVH RXU DPSOL HU SURGXFWV ZLWK DQ FRROLQJ vents cover...

Page 6: ...ioned above the power stage is very musical it has a very sweet tone and handles being pushed into distortion which is a very big test on any EDVV SURGXFW ZLWK HDVH DQG ZLWKRXW DQ XOWUD KDUVK unpleasantness it really delivers the goods with what ZH WKLQN LV D SUHWW VXSHUE VRXQG OHYHO 63 IRU DQG 300 watt bass rigs To keep things cool the power amp is thermostatically fan cooled on a very large heat...

Page 7: ...series EH VWDFNHG RQ WRS RI WKH OELRQ 6 FDELQHW VSOLWWLQJ the system into a 3 way bass system for increased bass response and wider spread when required but still making a compact transportable system ...

Page 8: ... even more possibilities LOW CUT when pushed in this switch activates a high SDVV OWHU V VWHP WKDW UROOV RI WKH YHU ORZ IUHTXHQFLHV LQ the preamp circuit which is used to tighten up the sound when the preamp is required to be pushed into overdrive for heavy rock playing styles This helps the sound to retain punch and drive without being swamped by the very low frequencies which can become muddy LO...

Page 9: ...ORRS it really will not sound good and be very very noisy If you have a good floor type processor then by all means experiment for your time delay type effects use the low level it may work it may not 7KH 5287 VZLWFK ZKHQ VHW WR SDVV GLVDEOHV WKH RRS circuit if not being used which is best practise if not using the effects loop LINE OUT the Line Out jack is fed post preamp and post FX Loop It is a...

Page 10: ...025 12AX7 ECC83 double triode small signal valves WXEHV 7KHUPRVWDWLFDOO DQ DQG SDVVLYH FRROHG 7 SRZHU RXWSXW stage 0DLQV XVH 9 VXSSO 7 WLPH ODJ 250V rated 20mm glass fuse 0DLQV XVH 9 VXSSO 7 WLPH ODJ 9 rated 20mm glass fuse 0DLQV XVH 9 VXSSO 7 WLPH ODJ 9 rated 20mm glass fuse 0DLQV XVH 9 VXSSO 7 WLPH ODJ 250V rated 20mm glass fuse DUQLQJ KHUH IXVHV VSHFL HG DUH UDWHG DW 9 SOHDVH be aware that this...

Page 11: ...OPERATING MANUAL AND USER GUIDE 7 ...

Page 12: ... GUIDE RXVH 6RYHUHLJQ RXUW UPLQH XVLQHVV 3DUN XQWLQJGRQ DPEV 3 8 QJODQG www albionamps com The information in this brochure is subject to change without notice All rights reserved 2010 Albion Albion is a member of the IAG Group ...

Reviews: