background image

GUIDA RAPIDA BILLYONE CCTALK

-

PULSE

 

 

 

 

 

 

Please pay attention: after any change in the DS settings, power must be turned off and then on again, so that the validator can detect the set operation mode. 

 
 
 
 
 
 
 
 
 
 

 

 

CCTALK COMMANDS 

 

CcTalk supported specifications list 

   

1. cctalk Generic Specification Issue 3.2 
2. cctalk Expansion for Bill Validators Issue2.1 

 

CcTalk supported commands list 

 

1. Core Commands 

 

Header 192 - Request build code 
Header 244 - Request product code 
Header 245 - Request equipment category id 
Header 246 - Request manufacturer id 
Header 254 - Simple poll

 

   
 

2. Core Plus Commands 

 

Header 001 - Reset device 
Header 004 - Request comms revision 
Header 241 - Request software revision 
Header 242 - Request serial number 

 

3. Bill Validator Commands 

 

Header 145 - Request currency revision 
Header 152 - Request bill operating mode 
Header 153 - Modify bill operating mode 
Header 154 - Route bill  

 

Header 156 - Request country scaling factor 
Header 157 - Request bill id 
Header 159 - Read buffered bill events 
Header 197 - Calculate ROM checksum 
Header 213 - Request Option flags 
Header 216 - Request data storage availability 
Header 227 - Request inhibit status 
Header 228 - Modify master inhibit status 
Header 230 - Request inhibit status 
Header 231 - Modify inhibit status 
Header 247 - Request variable set 

Luminescent Signals 

 

 

 

 

AF Modes (Anti-fraud) 

 

nr red 

flashes 

 

Description 

   

 

Validator is open 

Jammed banknote 

Fraud attempted 

Adjust optics  

Low power supply 

11 

Check motor efficiency 

12 

14 

ROM error 

 
 
 
 
 
 

 

®

 

   

P

ROGETTAZIONE E PRODUZIONE DI SISTEMI DI PAGAMENTO

,

 ACCESSORI PER VIDEOGAMES E MACCHINE VENDING

 

D

ESIGN AND MANUFACTURE OF PAYMENT SYSTEMS

,

 ACCESSORIES FOR VIDEOGAMES AND VENDING MACHINES

 

 

Via Ca’ Bianca 421   

40024  Castel San Pietro Terme (BO) - ITALY 

Tel.  + 39 051 944 300 
Fax. + 39 051 944 594 

http://www.alberici.net 

[email protected] 

 

SW Nr 

DIP-SWITCH FUNCTION 

SW 1 

OFF 

Normal acceptance -  High security 

ON 

Widened acceptance – Low security 

SW 2 

OFF 

Anti-fraud with warning enabled, (see ** in Table 

AF Modes below), 5 at temporary inhibit 

ON 

Anti-fraud with warning disabled, (see * in Table AF Modes 

below) 

 

SW 3  

and

  

SW 4

 

 

 

SW 3 

SW 4 

Set up of slot luminescence 

OFF 

OFF 

Changing colours  

ON 

OFF 

Green 

OFF 

ON 

Blue 

ON 

ON 

White 

 
 

SW 5 

  

  

Serial modes (Dip-Sw8=OFF) 

Pulse Mode (Dip-Sw8=ON) 

SW 5 

Function 

SW 5 

Pulse width 

OFF 

n.d. 

OFF 

100msec./100msec. 

ON 

n.d. 

ON 

200msec./200msec. 

  

  

 

 

SW 6  

and  

SW 7 

 

  

Serial modes (Dip-Sw8=OFF) 

 Pulse Mode (Dip-Sw8=ON) 

SW 6 

SW 7 

Operating mode (protocol) 

SW 6 

SW 7 

Pulse number 

OFF 

OFF 

ccTalk 

OFF 

OFF 

5 euro = 1 pulse 

ON 

OFF 

n.d.

 

ON 

OFF 

5 Euro = 5 pulses 

OFF 

ON 

n.d.

 

OFF 

ON 

10 Euro = 5 pulses (5 € disabled)    [v. 2.02 on]

 

ON 

ON 

n.d.

 

ON 

ON 

5 Euro = 10 pulses   [v. 2.02 on]

 

  

  

 

SW 8 

OFF 

Serial mode (Select by Dip-switch 6 + 7: ex. ccTalk: SW6=OFF e SW7=OFF) 

ON 

Pulse mode 

Pin 

Signal 

Function 

 

Pin 

Signal 

Function 

CCT 

CCT Data (active low) 

 

NC 

Not connected 

NC 

Not connected 

Vcc 

+ 12 / 24 Vdc (Power supply) 

NC 

Not connected 

Vss 

GND (Power supply) 

NC 

GND 

NC 

Not connected 

NC 

Not connected 

10 

Vcc 

+ 12 / 24 Vdc (Power supply) 

Pin 

Signal 

Function 

 

Pin 

Signal 

Function 

INH+ 

Inhibit (GND = enabled) 

 

NC 

Not connected 

NC 

Not connected

 

Vcc 

+ 12 / 24 Vdc (Power supply) 

NC 

Not connected

 

Vss 

GND (Power supply) 

NC 

GND 

VEND 

Credit out (active low) 

NC 

Not connected 

10 

Vcc 

+ 12 / 24 Vdc (Power supply) 

 

(*)  Dip-Switch SW2 ON    

After fraud attempts, the validator returns the banknote. No signal given.  

 
 

 (**)  Dip-Switch SW2 OFF   

Attempt 

Validator reaction 

Do as described below 

1° 

Remains in service 

2°  

Remains in service 

3° 

>  error (3 red flashes) 

Reset (switch off then on) 

… 4° … 

>  error (3 red flashes) 

Reset (switch off then on) 

After the 5th fraud attempt (3 yellow flashes), it is necessary to wait for automatic 

restore of service. Take care not to switch the device off. 

 

 

Reviews: