AL55/66 Technical manual Version 1.1
Table 5.2: Coin value programming
Table 5.3: Coin sorting direction programming
5.2.3 Advanced self-programming mode2
This mode is enabled only for parallel validator if both DIP-sw banks are available.
DIP-sw bank 1 is used to select coin channel and status to program in same way as in
mode 1. DIP-sw bank 2 is used to select activation output of programmed channel
according to table 5.4.
Table 5.4: Output activation selection
Switch 1 to 6 are representing activation mask of outputs 1 to 6.
Multiple output activations are allowed and used in parallel combinatorial type!
18
Coin value
Sw1
Sw2
Sw3
Sw4
Sw5
Sw6
No Change
Off
Off
Off
Off
X
X
1
On
Off
Off
Off
X
X
2
Off
On
Off
Off
X
X
4
On
On
Off
Off
X
X
5
Off
Off
On
Off
X
X
8
On
Off
On
Off
X
X
10
Off
On
On
Off
X
X
20
On
On
On
Off
X
X
25
Off
Off
Off
On
X
X
40
On
Off
Off
On
X
X
50
Off
On
Off
On
X
X
80
On
On
Off
On
X
X
100
Off
Off
On
On
X
X
125
On
Off
On
On
X
X
200
Off
On
On
On
X
X
250
On
On
On
On
X
X
DIP-sw bank 2
Direction
Sw1
Sw2
Sw3
Sw4
Sw5
Sw6
No Change
Off
Off
Off
Off
Off
Off
1
X
X
X
X
Off
Off
2
X
X
X
X
On
Off
3
X
X
X
X
Off
On
4
X
X
X
X
On
On
DIP-sw bank 2
Sw1
Sw2
Sw3
Sw4
Sw5
Sw6
Out nr.
1
2
3
4
5
6
Pin
7
8
9
10
3
4
DIP-sw bank 2