Albercorp RT3-100L User Manual Download Page 2

 

 

1. Warranty and Limitation of Liability 
  
LIMITED WARRANTY 
 
Albércorp warrants that the software product will perform in accordance with the accompanying written 
materials for a period of ninety (90) days from the date of receipt. Some states and jurisdictions do not 
allow limitations on duration of an implied warranty, so the above limitation may not apply to you. To the 
extent allowed by applicable law, implied warranties on the software product, if any, are limited to ninety 
(90) days. 
 
CUSTOMER REMEDIES 
 
Albércorp's entire liability and your exclusive remedy shall be, at Albércorp's option, either return of the 
price paid, or replacement of the software product that is returned to Albércorp with proof of purchase. This 
Limited Warranty is void if failure of the software product has resulted from accident, abuse or 
misapplication. Any replacement software product will be warranted for the remainder of the original 
period or thirty (30) days, whichever is longer. 
 
Albércorp shall not be liable for any data or programs stored in or used in conjunction with this software 
product. Without prejudice to the foregoing generality, Albércorp shall not be liable for the loss or 
corruption of data or programs stored in or used in conjunction with this or any other software product, nor 
shall Albércorp be liable for the cost of retrieving or replacing lost or corrupted data. 
 
Albércorp's sole and exclusive liability, for any and all losses and damages arising out of any cause 
whatsoever, shall in no event exceed the purchase price of the software product purchased. 
 
NO LIABILITY FOR CONSEQUENTIAL DAMAGES 
 
Albércorp shall not in any case be liable for any damages, including special, incidental, indirect, 
exemplary, collateral or consequential, arising from breach of warranty, breach of contract, negligence or 
under any other legal theory arising from the warranty herein stated or the purchase of product, including, 
without limitation, loss of profits, use or goodwill. 
 
Some states and countries do not allow the exclusion or limitation of incidental or consequential damages; 
therefore, the above exclusion or limitation may not apply to you. This warranty gives you specific legal 
rights, and you may also have other rights which vary state to state and country to country. 
 
 
2. Software License Agreement 
 
THIS IS A LEGAL AGREEMENT. PLEASE READ BEFORE INSTALLING SOFTWARE. 
 
Any use of this media other than to review this Software License Agreement constitutes your acceptance of 
and agreement with the terms of this Software License Agreement with respect to the Albércorp Software. 
If you do not accept and agree to these terms, you must return the full product with proof of purchase to 
Albércorp within thirty (30) days for a full refund. Installation or use of this software product constitutes 
your acceptance of and agreement with the terms of this Software License Agreement.  
 
LICENSORS. All software on this media is licensed to you by Albércorp. 
 
GRANT OF LICENSE. You are granted the right to use the Albércorp Software on a single personal 
computer. You may copy the software to use with this personal computer to any one hard disk drive of this 
personal computer and to the memory of this personal computer, provided that you reproduce all copyright 
and trademark notices, restricted rights legends, and other proprietary markings. 
 

Summary of Contents for RT3-100L

Page 1: ...RT3 100P 100L Digital Micro Ohmmeters User s Guide 990 South Rogers Circle Suite 11 Boca Raton FL 33487 Tel 561 997 2299 Fax 561 997 5588 www alber com...

Page 2: ...d NO LIABILITY FOR CONSEQUENTIAL DAMAGES Alb rcorp shall not in any case be liable for any damages including special incidental indirect exemplary collateral or consequential arising from breach of wa...

Page 3: ...l be acquired shipped transferred or exported directly or indirectly into any country or used for any purpose except as authorized by the Act and the regulations GENERAL This Software License Agreemen...

Page 4: ...If liquid does get into the equipment unplug it immediately and contact your nearest authorized service center or Alb rcorp directly Ensure equipment is provided adequate ventilation Do not block equ...

Page 5: ...7 5 1 OPERATING PRINCIPLE 7 5 2 MEASUREMENT ACCURACY 7 5 3 ERROR MONITOR 8 5 4 OPERATING TEMPERATURE 8 5 5 OVERRANGE INDICATION 8 5 6 CONNECTING TO THE LOAD 8 5 7 CIRCUIT BREAKER TESTING 9 6 BATTERIES...

Page 6: ...t reported to the shipper You should also verify the items received match the packing slip Alb rcorp is not responsible for missing items not reported within ten days after receipt by the customer 1 1...

Page 7: ...al describes both the RT3 100P and the RT3 100L If a feature applies to both models then the reference RT3 100 is used Instrument operation consists of selecting the required measuring range and press...

Page 8: ...ate the test 2000 Microhms 20 Milliohms switch Selects the appropriate resistance range for the load under test Long Short Pulse Mode switch Selects the length of time a test current is applied Does n...

Page 9: ...ximum indications are 1999 microhms or 19 99 milliohms If the resistance under test exceeds the selected range an overrange indication 1 followed by three spaces appears Error LED Lights if the load c...

Page 10: ...he load under test The available ranges are 2000 microhms and 20 milliohms Continuous Off Momentary Test switch Selects the length of time test current is applied Activates the test When set to Moment...

Page 11: ...exceeds the selected range an overrange indication 1 followed by three spaces appears Error LED Lights when the test leads are connected to an energized circuit When such a connection error occurs te...

Page 12: ...ce 5 2 Measurement Accuracy In practice total resistance in the test current path varies with the changing load resistance and the test current can deviate from its nominal value However one of the ad...

Page 13: ...he operating temperature range The effect of cold temperature is a loss of battery capacity battery capacity at 0 F is approximately 75 of rated WARNING The unit may be charged only between 40 F to 85...

Page 14: ...d prior to connecting the RT3 100 unit Although the RT3 100 is protected against high static voltages it should not be used to discharge high voltages to ground If the circuit breaker under test has c...

Page 15: ...ut the charger connected When the Error LED remains lit at the end of a current pulse it indicates either a high load resistance or the batteries must be charged WARNING Do not use the instrument with...

Page 16: ...panel up Figure 4 RT3 100P Battery Replacement WARNING When connecting or disconnecting the internal battery leads do not reverse the leads or allow them to touch other circuits or the metal enclosure...

Page 17: ...the battery mounting plate E with batteries into the RT3 100P enclosure 13 Connect the 10V series connection wire C to the batteries 14 Connect the three positive battery connections B to the batterie...

Page 18: ...ds are positioned exactly at the calibration points and the small resistance between the screw head and the load is in series with the high input impedance of the meter circuit thus being totally insi...

Page 19: ...ductive loads such as circuit breakers with current transformers 8 Press the Read button In about one second for resistive load or after the reading has settled for inductive load the meter displays t...

Page 20: ...can be taken in quick succession without affecting the accuracy of the instrument however repeated readings can cause internal heating CAUTION To prevent instrument damage from excessive heating do n...

Page 21: ...mers 8 In about one second for resistive load or after the reading has settled for inductive load the meter displays the resistance of the equipment under test This reading is displayed until either t...

Page 22: ...current is below 88 amps and should go out at the end of the current pulse when the current flow is 90 amps or greater The Error LED threshold setting is not critical and the tolerances may be opened...

Page 23: ...ration adjustments on the PC board remove the six main panel screws and lift the panel up This exposes the PC board Adjust the unit as follows 1 Connect the RT3 100L potential and current leads to the...

Page 24: ...Battery Replacement 13 Spare Parts List Item Part Number AC Cable 1100 009 Potential Leads 20 ft ML 100 Current Leads 20 ft ML 230 Spiked Probe Leads w read button 20 ft ML 301 Spiked Probe Leads w o...

Page 25: ...tion 0 to 1999 microhm range 1 microhm 0 1 optional 0 to 19 99 microhm range 10 microhms Temperature Coefficient Less than 0 02 per C Range 0 to 1999 microhms 0 to 19 99 microhms Test Current 100 amps...

Page 26: ...w LED 6 current transformers 9 error LED 4 6 8 10 four wire principle 7 fuse 3 5 inductive load 14 16 kantwist mueller test lead 13 kelvin test lead 13 long mode 14 long short pulse mode switch 3 mete...