background image

- 52 - 

 

 

 

 

 

 

 

Appendix A – 

 

 

 

 

 

 

 

 

 

Summary of Contents for MK-1200ZB

Page 1: ...Wireless Linear Imager Scanner Configuration Guide MK 1200ZB ...

Page 2: ...x Suffix 7 2 3 Setup Insertion 8 Chapter 3 BarCode parameters setting 3 1 UPC A 12 3 2 UPC E 15 3 3 EAN 13 18 3 4 EAN 8 20 3 5 Code39 22 3 6 Codabar 25 3 7 Code93 29 3 8 Code128 31 3 9 Interleaved2 of 5 34 3 10 Industrial 2of 5 36 3 11 Matrix 2 of 5 38 3 12 China Postage 40 3 13 MSI Plessey 42 3 14 Code 32 44 3 15 Code 11 46 3 16 Telepen 48 3 17 GS1 DataBar 50 Appendix 52 ...

Page 3: ... need to change these settings programming is accomplished by scanning the bar codes in this guide 1 2 How to set up the parameter I 1 Scan Start Configuration 2 Scan all necessary labels for parameters that meet your applications 3 Scan End Configuration to end the programming Start configuration End configuration Default setting Check Version An asterisk next to an option indicate the default se...

Page 4: ...le reads are needed to complete the configuration When use these special parameters In some cases you might need to read one or more barcodes such as Hexadecimal barcodes For example prefix suffix etc Numeric barcodes For example inter character delay max min length To complete the change of setting you will need to read the Confirm barcode after you read the parameter Below is the flow chart to e...

Page 5: ... 6 Chapter 2 System setup Start configuration End configuration 2 1 Terminator ITEM OPTION None CR LF CR LF Tab Output Characters ...

Page 6: ...at Prefix Code ID Bar Code Suffix How to set up a prefix To configure as prefix 1 Scan Start Configuration barcode 2 Scan Preamble bar code 3 Scan twice from FULL ASCII table 4 Scan Confirm configuration barcode 5 Scan End Configuration barcode How to set up a suffix To configure as suffix 1 Start configuration barcode 2 Scan Postamble barcode 3 Scan twice from FULL ASCII table 4 Scan Confirm conf...

Page 7: ... This section describes how to setup the insertion of output NOTE Max 10 charters can be inserted each time Max Insertion group is only two Insertion group 01 or 02 can be used in different kinds of barcodes at the same time ...

Page 8: ...ou wish to place the character 6 Scan Start Configuration barcode 7 Scan G1 Character Position 8 Scan 0 and 3 from FULL ASCII Table which presents the position 9 Scan Confirm configuration barcode 10 Scan End configuration barcode How to set up insertion for code 39 Go to chapter 3 5 code 39 11 Scan Start Configuration barcode 12 Scan Insert group selection bar code 13 scan 0 and 1 from FULL ASCII...

Page 9: ...eamble Default 00 Ref Appendix Postamble Default 00 Ref Appendix G1 Insertion character Default 00 Ref Appendix G2 Insertion character Default 00 Ref Appendix G1 Character Position to be inserted Default 00 Ref Appendix G2 Character Position to be inserted Default 00 Ref Appendix ...

Page 10: ...uracy Read 2 Times Negative bar codes Positive and negative bar codes Positive bar codes Code Type ID Code Type ID UPC A F Interleaved 25 N UPC E G Industrial 25 O EAN 13 H Matrix 25 P EAN 8 I China Postal Code Q Code 39 J MSI Plessey R Codabar K Code 32 S Code 93 L Code 11 T Code 128 M Telepen V ...

Page 11: ... to the ASCII Table and scan label that represent the desired characters to be inserted 3 Scan Confirm configuration bar code 4 Scan End configuration bar code Start configuration End configuration Confirm configuration 3 1 UPC A ITEM OPTION Disable Read Enable Code ID Setting Default F Ref Appendix 20 7EH ...

Page 12: ...PTION Disable UPC A Expand to EAN 13 Enable Disable Check Digit Send Enable Disable Truncate Leading Zero Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix 00 0DH Insert group selection Ref Appendix 00 02H ...

Page 13: ... 14 Start configuration End configuration ITEM OPTION NONE 2 digits 5 digits 2 or 5digits Supplement digits Auto discriminate Supplement ...

Page 14: ... 15 3 2 UPC E Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default G Ref Appendix 20 7EH ...

Page 15: ...ration ITEM OPTION Disable UPC E Expand to UPC A Enable Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H Truncate Ending Default 00 Ref Appendix 00 08H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 16: ... 17 Start configuration End configuration ITEM OPTION Disable Truncate Leading Zero Enable None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement ...

Page 17: ...ration End configuration ITEM OPTION Disable Read Enable Code ID setting Default H Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix 00 0DH ...

Page 18: ...figuration End configuration ITEM OPTION None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Disable ISBN ISSN Conversion Enable Insert group selection Default 00 Ref Appendix 00 02H ...

Page 19: ...3 4 EAN 8 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default I Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H ...

Page 20: ...ation End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 08H None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Insert group selection Default 00 Ref Appendix 00 02H ...

Page 21: ...2 3 5 Code39 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default J Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 22: ...tart configuration End configuration ITEM OPTION Disable Append Enable Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H Standard Code39 Format Code 39 Full ASCII ...

Page 23: ...n End configuration ITEM OPTION Disable Transmit Start End Character Enable Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 24: ... 25 3 6 Codabar Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default K Ref Appendix 20 7EH ...

Page 25: ... 26 Start configuration End configuration ITEM OPTION Disable Check sum verification Enable Disable Check sum transmission Enable Disable Append Enable Truncate Leading Default 00 Ref Appendix 00 7EH ...

Page 26: ...iguration End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 7EH ABCD ABCD abcd abcd Start End type abcd tn e Disable Start End transmission Enable Min code length Default 05 Ref Appendix 00 3CH ...

Page 27: ... 28 Start configuration End configuration ITEM OPTION Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 28: ... 29 3 7 Code93 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default L Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 29: ...e Check sum transmission Enable Min code length Default 00 Ref Appendix 0 50H Max code length Default 50H Ref Appendix 0 50H Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Insert group selection Ref Appendix 00 02H ...

Page 30: ... 31 3 8 Code 128 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default M Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 31: ... 32 Start configuration End configuration ITEM OPTION Disable Check sum transmission Enable Disable FNC2 Append Enable Disable UCC EAN128 Enable Disable FNC1 transmission Enable ...

Page 32: ...RACTER Enable Field Separator Ref Appendix Truncate Leading Default 00 Ref Appendix 00 7FH Truncate Ending Default 00 Ref Appendix 00 7FH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 33: ...Interleaved 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default N Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 34: ...PTION Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Min code length Default 04 Ref Appendix 04 7FH Max code length Default 7FH Ref Appendix 00 7FH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 35: ...l 2 of 5 Start configuration End configuration ITEM OPTICON Disable Read Enable Code ID setting Default O Ref Appendix 20 7EH Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H ...

Page 36: ...ion ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Disable Check sum verification Enable Disable Check sum transmission Enable Insert group selection Default 00 Ref Appendix 00 02H ...

Page 37: ... 38 3 11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default P Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 38: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 0B Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 39: ... CHINA POSTAL CODE Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default Q Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 40: ...PTION Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 41: ... 42 3 13 MSI Plessey Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default R Ref Appendix 20 7EH Disable MOD 10 MOD 10 10 Check sum verification MOD 11 10 ...

Page 42: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 3CH Truncate Ending Default 00 Ref Appendix 00 3CH Min code length Default 00 Ref Appendix 00 3CH Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 43: ... 3 14 CODE 32 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID Setting Default S Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Enable ...

Page 44: ... 45 Start configuration End configuration ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 0AH Truncate Ending Default 00 Ref Appendix 00 0AH Insert group selection Default 00 Ref Appendix 00 02H ...

Page 45: ... 46 3 15 CODE 11 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default T Ref Appendix 20 7EH Disable Check sum verification Enable ...

Page 46: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 47: ...8 3 16 Telepen Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default V Ref Appendix 20 7EH Disable Check sum verification Enable Only Numnic Data Format Full ASCII ...

Page 48: ... sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 40H Truncate Ending Default 00 Ref Appendix 00 40H Min code length Default 00 Ref Appendix 00 40H Max code length Default 40H Ref Appendix 00 40H Insert group selection Default 00 Ref Appendix 00 02H ...

Page 49: ... 50 3 17 GS1 Data Bar RSS Start configuration End configuration ITEM OPTION Enable RSS 14 Disable Enable RSS 14 LIMITED Disable Enable RSS 14 EXPANDED Disable Enable RSS TO UPC EAN Disable ...

Page 50: ... 51 Start configuration End configuration ITEM OPTION Enable APPLICATION ID TRANSMISSION Disable Enable CHECKSUM TRANSMISSION Disable ...

Page 51: ... 52 Appendix A ...

Page 52: ... 6 F V f v 7 BEL Left ETB F7 7 G W g w 8 BS Backspace CAN F8 8 H X h x 9 HT TAB EM F9 9 I Y i y A LF LF SUB F10 J Z j z B VT Right ESC F11 K k C FF PageUp FS F12 L l D CR Enter GS ESC M m E SO PageDown RS N n F SI US O _ o DEL Note 1 If scan the following barcode the output data pleaser refer to type 1 in blue Type 1 Note 2 If scan the following barcode the output data please refer to type 2 in re...

Page 53: ...9 HT 41 29 10 0A LF 42 2A 11 0B VT 43 2B 12 0C FF 44 2C 13 0D CR 45 2D 14 0E SO 46 2E 15 0F SI 47 2F 16 10 DLE 48 30 0 17 11 DC1 49 31 1 18 12 DC2 50 32 2 19 13 DC3 51 33 3 20 14 DC4 52 34 4 21 15 NAK 53 35 5 22 16 SYN 54 36 6 23 17 ETB 55 37 7 24 18 CAN 56 38 8 25 19 EM 57 39 9 26 1A SUB 58 3A 27 1B ESC 59 3B 28 1C FS 60 3C 29 1D GS 61 3D 30 1E RS 62 3E 31 1F US 63 3F ...

Page 54: ...73 49 I 105 69 i 74 4A J 106 6A j 75 4B K 107 6B k 76 4C L 108 6C l 77 4D M 109 6D m 78 4E N 110 6E n 79 4F O 111 6F o 80 50 P 112 70 P 81 51 Q 113 71 q 82 52 R 114 72 r 83 53 S 115 73 s 84 54 T 116 74 t 85 55 U 117 75 u 86 56 V 118 76 v 87 57 W 119 77 w 88 58 X 120 78 x 89 59 Y 121 79 y 90 5A Z 122 7A z 91 5B 123 7B 92 5C 124 7C 93 5D 125 7D 94 5E 126 7E 95 5F _ 127 7F DEL ...

Page 55: ... 56 Table Hex HEXADCIMAL Confirm configuration End Configuration ...

Page 56: ...Version 3 21 ...