![Albalá Ingenieros GTI2000C01 Manual Download Page 16](http://html.mh-extra.com/html/albala-ingenieros/gti2000c01/gti2000c01_manual_2889191016.webp)
Albalá Ingenieros | Manual
GTI2000C01
OK(B). Cyan. For both Automatic and Semiautomatic modes this color indicates
that the module is using the internal 10MHz reference and also that no reference
signal is present on the front panel input.
OK(F). Yellow. For both Automatic and Semiautomatic modes this color indicates
that the module is using the front panel reference signal and also that no valid
10MHz internal signal is present.
FAIL. Red. For both Automatic and Semiautomatic modes this color indicates that
neither of the reference signal sources are providing a valid signal. In Manual
mode this color indicates that the selected input does have a valid reference
signal present.
The following table displays the behavior of this LED as a function of the operating
mode, the input selected and the status of the reference inputs:
MODE
SELECTED
REFERENCE
INTERNAL REF.
STATUS
FRONT REF.
STATUS
STAT.
FULL AUTO
HALF AUTO
X
FAIL
FAIL
FAIL. RED
INTERNAL
OK
OK
OK (B). BLUE
FRONT
OK
OK
OK (F). GREEN
INTERNAL
OK
FAIL
OK (B). CYAN
FRONT
OK
FAIL
FAIL. RED
INTERNAL
FAIL
OK
FAIL. RED
FRONT
FAIL
OK
OK (F). YELLOW
MANUAL
INTERNAL
FAIL
X
FAIL. RED
INTERNAL
OK
X
OK (B). BLUE
FRONT
X
FAIL
FAIL. RED
FRONT
X
OK
OK (F). GREEN
4.2. Functional description
The GTI2000C01 is a generator for 2048kHz synchronization signals as per ITU-T G.703.
It can operate while locked to the internal 10MHz reference signal of the mounting
frame in which it is installed whenever the frame has a GPS2000C01 GNSS module to
generate the 10MHz signal. The GTI2000C01 can also lock to 2048kHz synchronization
signals present at the front panel connector labelled IN on the silkscreening.
The GTI2000C01 has three operating modes, described as follows:
- Manual: the user specifies which reference input the 2048kHz oscillator will lock to
at all times. If no valid reference is available at the selected input then the oscillators
operates in free running mode.
- Full auto: the reference input to which the oscillator locks is whichever input is
present and has the higher priority. This means that in the case of a signal failure at
the higher priority input the oscillator switches and locks to the lower priority input.
It then switches back to the higher priority input if this becomes available again. If
neither of the two input reference signals are present, the oscillator operates in free
16
Summary of Contents for GTI2000C01
Page 2: ...GTI2000C01 ...
Page 4: ...GTI2000C01 ...
Page 7: ...Albalá Ingenieros Manual GTI2000C01 1 3 Block diagram 7 ...
Page 8: ...Albalá Ingenieros Manual GTI2000C01 GTI2000C01 8 ...
Page 10: ...Albalá Ingenieros Manual GTI2000C01 GTI2000C01 10 ...
Page 14: ...Albalá Ingenieros Manual GTI2000C01 GTI2000C01 14 ...
Page 21: ...Albalá Ingenieros Manual GTI2000C01 5 GLOSSARY 21 ...
Page 22: ...Albalá Ingenieros Manual GTI2000C01 GTI2000C01 22 ...
Page 24: ...Albalá Ingenieros Manual GTI2000C01 GTI2000C01 24 ...