60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
•
Number of attempts before lockout must be 1-9 attempts.
•
The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
•
The attempt count is reset each time a valid code is entered.
•
Lockout Time must be 1-60 seconds.
How long the keypad is locked-out after a series of unsuccessful attempts
(default is 18 seconds).
4
4
LOCKOUT
; 6 4 :
64. Disable Remote Input
•
Wire a Normally Open Contact to Wires (White & White) for a Remote Input. Momentarily close
switch to unlock the lock to allow person to pass through door. This Remote Input can be used to
control the Aux Relay. See the Aux Relay System Features on page 27 (Function 67).
•
Enter the functions below to Disable/Enable the Remote Input.
NOTE:
The Remote Input is enabled in the factory default.
Remote Input
; 6 5 :
65. Enable Remote Input
; 6 6 ;
[ _ _ ]
:
(Ambush Code)
66. Ambush Code
•
Ambush code must be 2 digits.
•
An error will sound if the Ambush Code matches the 1st two digits of any User Code.
See Function 67 for more information about the Ambush Function.
2
3
REMOTE INPUT
AMBUSH
; 6 0 ;
[ _ ]
:
(Number of Attempts)
; 6 1 ;
[ _ _ ]
:
(Lockout Time)
62-63. Reserved
Programming Functions (cont'd)
59. Reserved
Summary of Contents for Trilogy PDK3000 Series
Page 39: ...39 NOTES ...