2
Figure 2: Hook Up
FROM
PP100
RED
WIRE
WHITE
WIRE
PLUG 2
(TO DEVICE TO
BE POWERED)
PLUG 1
(TO BATTERY PACK-
-ACTS AS BACKUP)
Figure 3: Adapter for 9V Units
TO PP100
PLUG 1
(SEE FIGURE 2)
TO UNIT TO BE
POWERED
TO BATTERY (ACTS AS BACKUP)
INSTRUCTIONS TO ADD CABLE NOTCH
For devices that allow power to be accessed from be-
hind the device
(with the power cable accessed from inside
a wall or other location), a ¾" hole can be drilled directly into
the rear chassis of the device.
For surface mounted devices
where the PP100 and its
armored power cable are mounted to a surface (such as a
wall or a rear door surface as shown in Figure 1), a ½" hole
and cable notch "slot" must be cut into the side of each de-
vice's alarm box or lock cover (see Figures 4-7).
In either case, the hole and/or cable notch must be large
enough to allow the insertion of Plug #2 (see Figure 2). For
surface mounted devices, the cable notch must secure the
armored cable and its retaining "C" ring (supplied).
1. Drill a ½" hole along the edge of the cover or box and
make a 1/8" wide slot from the hole to the edge. See
Figures 4-7.
2. Insert cable bushing through hole and secure with "C"
ring inside.
3. Plug connectors together as per the instructions on the
previous page.
Figure 4: Cable Notch location for 11A Series
½" hole
and cable
notch
"slot"
Edge of box
or cover
½" hole
½"
1/8" slot
Figure 5: Cable Notch location for PG10 and LL-1 Series (PG21 similar)
½" hole
and cable
notch
"slot"
Edge of box
or cover
½" hole
½"
1/8" slot
Figure 6: Cable Notch location for 700 Series
½" hole
and cable
notch
"slot"
½" hole
1"
1/8" slot
9
/
16
"
Figure 7: Terminal Strip inside DL Series of Locks
+
–
External
Supply
[+] Red
[–] Black
Optional DC
Power Input
6-9 Volt DC
Remote
Release
Battery
Connector
NO
NC
C
(Relay)
Motor
Connector
RED
WIRE
BLACK
WIRE