background image

1

Trilogy Series

PDL3000 Programming Instructions

WI1021 10/00

© ALARM LOCK 2000

ALARM LOCK

ALARM LOCK

PDL3000 Trilogy Series

Standalone Access Control System

with ProxCard Access

 PLUG IN THEN

 ENTER YOUR CODE

H I D

H I D

HID CORPORATION

Prox

Card

Reader

AL-DTM (Version 1)/AL-DTM2

DATA TRANSFER MODULE

PROX CARD READER

AR-IR1 PRINTER

PROX CARD

KEYFOB

Summary of Contents for PDL3000 series

Page 1: ...K 2000 ALARM LOCK ALARM LOCK PDL3000 Trilogy Series Standalone Access Control System with ProxCard Access PLUG IN THEN ENTER YOUR CODE H I D H I D HID CORPORATION Prox Card Reader AL DTM Version 1 AL DTM2 DATA TRANSFER MODULE PROX CARD READER AR IR1 PRINTER PROX CARD KEYFOB ...

Page 2: ...acement 7 Power Up Retain Lock Programming 7 Power Up Erase all Programming 7 Preliminary Information 8 Lock Operation 8 Programming Notes 8 Programming Information 8 Visible LED and Audible Sounder Indicators 8 Getting Started 9 Battery Installation 9 Entering Program Mode 9 Setting the Clock 9 User Programming 10 Programming the PDL3000 for Prox Card Access 10 High Security Access Prox Card User...

Page 3: ... will Override 20 47 Timed Passage Mode 20 48 50 Passage Mode Enable Disable Schedule will not Override 21 51 Passage Mode Configuration 21 52 54 Pass Time 21 55 57 Printer Functions 22 58 Upload Download PC Data 22 59 AL DTM2 Door Number 23 60 61 Lockout 23 64 65 Remote Input 23 66 Ambush Code 23 67 68 Relay System Features 24 69 70 Enter Key 25 72 73 Scheduled Passage Mode Unlock Lock 25 74 83 S...

Page 4: ...ocks AL DTM2 to upload multiple lock logs AUDIT LOG 08 25 00 13 06 35 Tue 13 01 59 001 PROGRAM 56 13 01 29 001 PROGRAM 57 13 00 53 001 ENTRY 13 00 26 013 ENTRY 13 00 03 012 ENTRY 12 56 27 001 PROGRAM 2 12 56 27 001 PROGRAM 40 12 56 04 001 PROGRAM 39 12 55 00 NEW CLCK TIME 12 01 39 OLD CLCK TIME 12 00 45 RAM TEST PASS 12 00 45 POWER UP End of Audit Log The Alarm Lock PDL3000 Series Trilogy Standalo...

Page 5: ...rail from multiple locks and then view or print each Audit Trail from a computer AL DTM version 1 may be used however limited to 48 Locks and the first 100 users AL IR1 Infrared Printer Optional hand held infrared printer may be used to print the Audit Trail and User Code List ALARM LOCK Prox Card Reader Prox Card Reader Optional Prox Card Reader allows quick and easy programming of Prox Cards and...

Page 6: ...r or by an automatic schedule function of the alarm panel Example Open window at 7 00AM using Program Function 90 Close Window at 8 30AM using Function 91 The relay will close one time only when a member of Group 1 enters their code between 7 00AM and 8 30AM Group 1 Member Enables Group 4 Users 1 Use Function 92 to set the time to open the window allowing any Group 1 member to enable Group 4 2 Use...

Page 7: ...When a valid code is entered and the batteries are weak the lock LED will display a yellow color and the sounder will sound for 4 seconds The PDL3000 uses 5 AA size 1 5 volt alkaline batteries The lock will function with weak batteries however be sure to replace the batteries as soon as possible Remove the screw at the bottom of the housing and remove the cover Pull out the battery pack and replac...

Page 8: ...Installer Codes Users 2 3 Allow all functions except master code change Manager Codes Users 4 6 Can program all functions except functions relating to lock configuration no default group association Supervisors User 7 9 Can only program functions relating to day to day operation no default group association Print Only Codes Users 10 11 Allow access to print audit trail only Basic User Codes No pro...

Page 9: ...mmands to set the clock Program the Date 3 8 _ _ _ _ _ _ Date Program the Time 3 9 _ _ _ _ Time Program the Weekday 4 0 _ Day Program Daylight Saving Time 4 1 _ _ For Example To set time to 8 25 P M Enter 3 9 2 0 2 5 For Example To set time to 8 25 A M Enter 3 9 0 8 2 5 For Example August 25 2000 Enter 3 8 0 8 2 5 0 0 For day enter 1 for Sunday 2 for Monday 3 for Tuesday 4 for Wednesday 5 for Thur...

Page 10: ...the first digits of any other user code only the code with the least number of digits would be recognized Example If user codes 123 and 123456 are both entered in the system only code 123 would be recognized unless the ENTER Key has been enabled Function 69 To program user codes that match the first digits of other codes see program Function 69 An error will sound if you try to program a new user ...

Page 11: ...ed User 101 Present CARD for User 101 within 10 second period three beeps will sound at the keypad Beep Beep Beep User 102 Present CARD for User 102 within 10 second period three beeps will sound at the keypad Beep Beep Beep User 150 Present CARD for User 150 within 10 second period three beeps will sound at the keypad Beep Beep Beep Printer Functions AR IR1 PRINTER required 08 25 00 13 06 35 Fri ...

Page 12: ...ating there is 15 seconds left to press a key or Program Mode will timeout Tri Color Status LED Infrared LED Printer PC Interface AL DTM2 2 series of 4 Quick Beeps once the Exit Sequence has initiated BeepBeepBeepBeep BeepBeepBeepBeep The PDL3000 lock can also be programmed using Alarm Lock s AL DTM2 Data Transfer Module and a computer running Alarm Lock s DL WINDOWS Software AL DTM2 Keypad will B...

Page 13: ...r a valid card or keyfob has been presented to the PDL3000 Lock INVALID CARD The RED LED will flash several times and the sounder will beep several times after an invalid card or keyfob has been presented to the PDL3000 Lock Use Function 2 to re program the code Verifying High Security Access ProxCard User Code Test Prox Card programmed for High Security Access in Getting Started for for User 15 A...

Page 14: ...isable All Groups 6 6 Ambush Code 1 9 2 2 Group 1 4 Enable 6 7 Add Relay System Features 2 3 Enable All Groups 6 8 Delete All Relay Functions and System Options added by Function 67 2 4 Reserved 6 9 7 0 Enable Disable Enter Key 2 5 2 8 Group Disable with Timeout 7 1 Reserved 2 9 Disable All Groups with Timeout 7 2 7 3 Scheduled Enable Disable Passage Mode 3 0 3 3 Group Enable with Timeout 7 4 7 7 ...

Page 15: ... 3 151 200 3 none Basic User Codes Group 4 201 250 4 none Basic User Codes 251 296 none none Quick Enable User 300 Code 297 none none Quick PC Access Code 298 none none AL DTM2 Code 299 none none Service Code 300 none none Basic User Codes 301 2000 none none 2 _ _ _ _ _ _ _ _ _ _ User Number User Number must be between 2 and 2000 To delete a code card leave the User Code blank and wait for the rap...

Page 16: ...0 Hours must be between 1 999 Can override a disabled user 2 1 0 0 0 0 10 Erase All Users Except the Master Service Code is a One Time Only Code Once it is used it is disabled until enabled again NOTE User Number 297 can also be used to reset Service Code Use 9 9 Enable User 300 Service Code Erases all user codes except the Master Code User 1 2 M 11 Reserved 3 Disable User 3 _ _ _ _ User Number 4 ...

Page 17: ... and Function 47 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions Scheduled Timeout features must be manually reset 3 3 13 Clear All Timeout Functions CLEAR FUNCTIONS 1 4 Group Enable Disable 1 5 16 Disable Group 3 1 6 17 Disable Group 4 1 7 18 Disable All Groups 1 8 19 Enable Group 1 1 9 20 Enable Group...

Page 18: ...groups to associate with user may be selected Add Example To associate user 67 with groups 1 2 and 4 Enter 3 5 6 7 1 2 4 Delete Example To remove all group associations for user 67 Enter 3 5 6 7 NOTE If a user is associated with more than one group all associated groups would have to be disabled before the user is disabled 2 6 _ _ _ XXX Hours 26 Timed Disable Group 2 2 7 _ _ _ XXX Hours 27 Timed D...

Page 19: ... CLOCK SETTINGS DST Mode Time Forwarded Time Regressed 01 No DST Adjustment 02 1st Sunday in March 4th Tuesday in Sept 03 Last Sat in March Last Sat in Sept 04 Last Sunday in March Last Sunday in Sept 05 Last Sunday in March 4th Sunday in Oct 06 Last Sunday in March Last Sunday in Oct 07 Last Sunday in March 1st Sunday in Sept 08 April 1st September 30th 09 April 1st October 1st 10 April 1st Last ...

Page 20: ...very day enter 4 4 1 3 This example assumes that the clock adjust setting was at the factory default of zero Function 57 can be used to print the current clock adjust setting Example 3 To set the clock adjust setting back to the factory default of zero enter 4 3 or 4 4 Clock Adjust 4 4 5 45 Enable Passage Mode 4 6 46 Disable Passage Mode 47 Timed Passage Mode 4 7 _ _ _ XXX Hours Allows passage thr...

Page 21: ...ble Schedule will not Override 2 PASSAGE MODE 4 9 48 Enable Passage Mode 4 8 5 0 5 2 52 Set Pass Time to 3 Sec 5 3 5 4 Use the functions below to change the pass time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds The Pass Time is the time the lock stays unlocked after a User Code is entered Pass Time 4 53 Set Pass Time to 10 Sec 54 Set Pass Time to 15 Sec PASS TIME See Scheduled fu...

Page 22: ...sensor as shown in Figure 1 and Figure 2 To abort printing press any key for 3 Sec Three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 For use with DL WINDOWS software refer to OI237 AL PCI interface cable is needed 1 3 3 PRINTER DOWNLOADING Hold the printer perpendicular to the Lock s infrared LED as shown in Figure 1 and Figure 2 If the...

Page 23: ...t program Remote Input 6 5 65 Enable Remote Input 6 6 _ _ Ambush Code 66 Ambush Code Ambush code must be 2 digits An error will sound if the ambush code matches the 1st two digits of any user code See Using Ambush Function on page 6 2 3 REMOTE INPUT AMBUSH 6 0 _ Number of Attempts 6 1 _ _ Lockout Time 62 63 Reserved 59 AL DTM2 Door Number Door Number must be between 1 96 Note Door Number must be b...

Page 24: ...Relay Follows Lock Unlock Status 4 System Options 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry Remote Input Functions 29 Remote Input Toggles Passage Mode 30 Forced Unlock Follows Remote Input 32 Remote Input Disables Unit Hold all States 34 Forced Lock Follows Remote Input Features 26 27 28 delay users 12 and greater only except 297 298 and 299 Feature...

Page 25: ..._ _ _ Day Time 80 Schedule Disable Group 2 8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule and Timeout Functions by entering Function 12 NOTE 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage Mode Lock 7 3 _ ...

Page 26: ...r Monday to Friday 9 for Saturday and Sunday 0 for all days of week Enter time of day in 24 hour format Enter the Open and Close Window Functions below to set up a Window where if any Group 1 User Code is entered within the programmed window Passage Mode will be activated See Group 1 Member in Puts Lock in Passage Mode on page 6 Scheduled Passage Mode Group 1 Activated 89 Passage Mode Close Time W...

Page 27: ...m option See Disarming a Burglar Alarm on page 6 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 Burglary Control Panel Relay Output Switch Input Alarm Panel with Switched Input for Disarming Burglary Control Panel Relay Output Switch Input External Relay Armed Lug Power Alarm Panel with Switched Input for Togg...

Page 28: ... for Thursday 6 for Friday and 7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday 0 for all days of week Enter time of day in 24 hour format Enter the Open and Close Window Functions below to set up a Window where if any Group 1 User Code is entered within the programmed window Group 4 will be enabled See Group 1 Member enables Group 4 Members on page 6 Scheduled Group 4 Enable Group ...

Page 29: ...ow Time of 6 A M 8 8 0 0 6 0 0 Enter the Close Window Time of 10 A M 8 9 0 1 0 0 0 The Lock will now be put in passage mode IF User 4 or any Group 1 User enters their code between 6 A M and 10 A M The Lock will have to be manually locked each night by entering the following command using Function 46 Manually close the Lock by entering the following command 4 6 The Lock can also be programmed to au...

Page 30: ...s 01 24 1 2 DST Code Check all that apply 1 Remote Input while enabled o o 2 Remote Input while disabled o o 3 Failed Entry Attempt o o 4 Disabled user entered code o o 5 Access Granted o o 6 Scheduled Group 1 Activated o o 7 Locked by Schedule o o 8 Unlocked by Schedule o o 9 Lock Out o o 10 Ambush Tripped o o 11 Any Key Press Card Entry o o 25 Disable Sounder o o 26 5 sec Delayed Entry o o 27 15...

Page 31: ...umber 1 2000 User Code 3 6 digits Group Association User Name 1 2 3 4 For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Software Note ...

Page 32: ...an be programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 33: ...CODE A code that has not been programmed in the lock MANAGER CODE User Code used by User 4 6 Allows most of the programming functions MASTER CODE User Code used by User 1 Default code is 123456 Master Code has complete control of the lock PRINT ONLY USER CODE User Code used by User 10 11 Allows no programming except print functions QUICK ENABLE USER 300 CODE User code 297 used to Re enable Service...

Page 34: ...r of invalid user code entries 1 9 that will disable the keypad for a predefined period of time 1 60 seconds LOCKOUT TIME A predefined time 1 60 seconds that the lock will stop accepting codes after a specified number of invalid user code entries 1 9 LOG See AUDIT TRAIL MANAGER See CODE MANAGER MASTER See CODE MASTER PASSAGE Allow anyone to pass through the door without USER CODES Door is Unlocked...

Page 35: ...ic weekday Sunday through Saturday and time SCHEDULES QUICK Any one of four most common types of schedules can be programmed TIME Hours and Minutes in the HHMM format TIME DATE STAMP A date and time that an event occurred TIMEOUT Immediate operation for a specified number of hours USER A person who has been provided with a USER CODE for access through the door USER LOCKOUT TOTAL All users except f...

Page 36: ...or authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the produ...

Page 37: ...ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver ...