![Alarm.Com ADC-IS-200-LP Installation Manual Download Page 4](http://html1.mh-extra.com/html/alarm-com/adc-is-200-lp/adc-is-200-lp_installation-manual_2888785004.webp)
Alarm.com Image Sensor
Installation Guide
4 Copyright © 2016 Alarm.com. All rights reserved.
Rev 3.5
from any test alarms from the Customer Website.
If the daughterboard LED is blinking, refer to this chart for LED trouble diagnostics.
Daughterboard Status LED Activity Reference
Z1 LED
Z2 LED
Device Status or Error
Duration of LED Pattern
Solid Red
Off
Daughterboard is
Receiving Power
While the daughterboard is
powered and the module is
not in power save mode.
Off
Off
Daughterboard Not
Receiving Power or
Module in Power Save
Mode
Until daughterboard receives
power or module returns
from power save mode.
Fast Blinks
Fast Blinks
Incompatible Module or
Hardware Issue
Module not compatible w/
Image Sensor (Firmware
146 & up required) or there
is a hardware failure.
Solid Red
4-blink
Daughterboard is in
Add-Mode
60 seconds or until device is
added.
Solid Red
Solid Green
Image Sensor Added
Successfully
Persists for 60 seconds.
Off on
Button
Press
Off
Panel in Programming
Mode; Daughterboard
Hardwire Tripped
Z1 Immediately returns to
solid red.
If the camera LED is blinking, refer to this chart for LED trouble diagnostics.
Image Sensor Red Status LED Activity Reference
Device Status
or Error
LED
Pattern
Duration of LED Pattern
Sensor Power-
Up
Solid for 5
Seconds
Approximately first 5 seconds after powering.
Sensor Joins or
Rejoins Network
Solid for 5
Seconds
First 5 seconds after sensor joins a new network
(during enroll process) or rejoins its existing
network.
Searching for
Network to Join
Fast Blink
for 5
Seconds at
a Time
Repeats pattern for up to 60 seconds after powering
until the sensor enrolls in a network.
Attempting to
Rejoin Network
Slow Blink
for 5
Seconds at
a Time
Repeats pattern for up to 60 seconds after power
cycle until the sensor reconnects to its network.
(Note: This means the sensor has already been
enrolled into a network and is trying to connect to it.
If attempting to enroll sensor in a new network, hold
reset button for a full 10 seconds (until LED blinks
rapidly) to clear the old network before adding to new
network.)
Motion Test
Mode
Solid for 3
Seconds at
a Time
Repeats for each motion activation during the 3
minutes after sensor joins network, has been
tampered, or is placed in PIR test mode. (Note: In
test mode, there is an
8 second “sleep” timeout
between motion trips.)
Network
Communication
Problem
Fast Blink
for 1
Second at
a Time
Pattern begins after 60 seconds of searching for (and
unsuccessfully joining) a network and repeats until
RF communication is restored. Pattern persists as
long as the sensor is not enrolled in a network or
cannot connect to current network.
TECHNICAL SPECIFICATIONS
Alarm.com Model Number
:
ADC-IS-200-LP
Interlogix Part Numbers
:
Image Sensor: 600-9400-IMAG
Image Sensor Kit (Image Sensor w/ daughterboard): 600-9400-IMAG-KIT
Power Source
:
Optimal: 2 AA 1.5v Energizer Ultimate Lithium Batteries. Acceptable: 2 AA
1.5v alkaline batteries (battery life may be reduced significantly).
Expected Battery Life
:
Approximately 2 years for lithium batteries. Battery life varies by
use case depending on certain factors such as weak signal strength and frequency of
motion activations, image captures, and IR flashes.
Voltage Thresholds
:
With lithium batteries, low battery alerts are issued at 3.05V. The
sensor cannot operate when the voltage reads below 1.95V.
Operating Temperature Range
:
32° to 110°F for non-pet applications, 60° to 110°F for
pet applications. Alkaline batteries are not suitable for temperatures below 50° F.
Weight
:
3.1 oz. (with batteries, without mounting accessories)
Dimensions
:
3.1’’ h x 1.8’’ w x 2.3’’ d
Supervisory Interval
:
100 minutes (sensor), 3 hours (alarm hardwire)
Wireless Signal Range
:
Greater than 400 ft open air
Color
:
White
Recommended Mounting Height
:
8 ft
Recommended Mounting Angle
:
6° for large coverage area and rooms greater than 30
ft (“teeth up” on mounting arm); 18° for rooms less than 30 ft (“teeth down” on mounting
arm)
Motion Profiles & Sensor Range
:
Normal (up to 30 ft, default), High (up to 35 ft), Low (up
to 25 ft)
REGULATORY INFORMATION
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the
interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a
circuit different form that which the receiver is connected. (4) Consult the dealer or an experienced radio/TV
technician for help.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
FCC ID: YL6-143IS20 IC: 9111A-143IS20