PRODUCT SUMMARY 

The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in 
camera. The sensor is designed to capture images during alarm or non-alarm events 
when motion is detected.  Users can also initiate image capture on-demand to  

Peek-In

 on their property. Images are stored locally and uploaded either automatically 

when motion is captured during alarm events or manually when requested by the user. 
Once uploaded, images are available for viewing on the Alarm.com Website or an 
Alarm.com smart phone app. The sensor is battery powered, all wireless and simple to 
install and operate. Both an Alarm.com module and a subscription to an Alarm.com 
service plan are required. 

 

Highlighted Features 

  Battery operated  

  Communicates wirelessly to the security control panel 

  35 feet by 40 feet detection coverage area 

  Configurable PIR sensitivity and pet immunity settings  

  Image: QVGA 320x240 pixels  

  Color Images (except in night vision) 

  Night vision image capture with infrared flash (black & white) 

  Tamper detection, walk test mode, supervision 

  

Service Plan Options 

Image capture features require either an Alarm.com Basic or Advanced

 

Interactive Service 

Plan and one of the following Image Sensor add-ons: 

 

Image Sensor Alarms

- Includes upload of images from alarm events only. 

 

Image Sensor Plus

- Includes upload of images from alarm events 

and

 non-alarm 

events. Users can configure 

Daily View

 schedules to receive images automatically each 

day or 

Peek-In

 to initiate an on-demand image capture immediately, or when the next 

motion occurs. Users can also request images that are captured automatically while the 
system is 

Armed Away

 or following a 

Disarm

 from an 

Armed Away

 state. Up to 40 

captured events can be uploaded per month. Additional image uploads may be added 
in increments of 20 at an additional charge. 

HARDWARE COMPATIBILITY  

 

Security Control Panel: 

Interlogix Concord 4.0 & Up*

 

 

Alarm.com Module

Concord CDMA module with firmware version 177 & up or any 

Concord HSPA module (Will show as firmware 173 & up) 

 

Required Daughterboard: 

Image Sensor daughterboard v104.0 & up (attached to 

compatible Alarm.com module) 

 

Available Zones: 

One zone per Image Sensor installed. One additional zone is 

required for the required daughterboard. Up to three Image Sensors may be added per 
system.

  

 
*For compatibility information and requirements for other platforms, visit 
www.alarm.com/Dealer

 

 

HARDWARE INSTALLATION

 

1. 

Create Alarm.com Customer Accoun

t-

 Select service plan (including Image Sensor 

add-on) and register the Alarm.com module serial number on the Alarm.com Dealer 
Website (www.alarm.com/dealer). 

 

2.  Install Image Sensor Daughterboard

-

 Locate the connector on the back of the 

daughterboard. Remove the green backing from the daughterboard mounting adhesive.  
While the module is powered down, align the daughterboard and module connector.  
Press to secure. Route the white daughterboard antenna down off the module into the 
bottom of the gateway. 

(NOTE: Verify module compatibility before attaching. Once attached, daughterboard is 
difficult to remove and removing may damage hardware.)

 

 
 

 

 
 

 

3. 

Connect Daughterboard Alarm Wire-

 

The included blue alarm hardwire must be 

connected from 

the “HW” hardwire output located on the daughterboard (use “HW” not 

“C”) to the “Z1” terminal on the Gateway to enable local alarm activations.  Connect a 
2.2kohm resistor from “Z1” to “GND” on the Gateway. The hardwire will be enrolled into 
the panel in step 6.   

 

(Note: The panel LCD will display an alarm on the alarm hardwire regardless of which 
Image Sensor tripped the alarm. The Alarm.com Website & notifications, and the 
central station report will indicate the specific Image Sensor that tripped the alarm.) 
 

 

 
 

4.  Register Module and Test

-

 

Power up the panel and initiate a comm-test to ensure the 

Alarm.com module is properly installed and communicating with the Alarm.com NOC.  

 

5.  Enroll Sensor in Panel

-

 

 

a. 

Begin with the batteries removed from the sensor and ensure the panel is not in 
System Programming.

 

b. 

Press button on IS daughterboard to enter ‘Add Mode.’ The green LED “Z2” will start 
a 4-

blink pattern indicating that the daughterboard is in ‘Add Mode’.  

 

c. 

Reset or insert the batteries into the image 

sensor. “Z2” will be solid for 60 seconds 

to indicate that the sensor has been added.

 

 
The Image Sensor 

WILL NOT show in the panel’s sensors menu as occupying a panel 

zone, but the zone must be reserved for the Image Sensor. It is enrolled starting with 
zone 92 and counts down.  The Alarm.com Dealer Site equipment list will show the 
Image Senor in its enrolled zone.  By default, the sensors are enrolled in partition 1 and 
group 17.  During step 6, the Image Sensors will be re-assigned to follow the partition 
and group of the hardwire.   
 

6.  Enroll Image Sensor Alarm Hardwire in Panel  

a. 

Enter sensor enrollment menu in System Programming 

b. 

Select the partition number, zone number, and sensor group for the hardwire. 

c. 

Trip daughterboard hardwire by pressing button on top of daughterboard. The red 
LED “Z1” on daughterboard will turn off when pressed. 

d. 

Exit system programming. The Image Sensors will now be assigned to the group 
and partition of the hardwire. 

e. 

Perform another panel comm-test to be sure that Alarm.com receives the updated 
device equipment list. This will speed up the sensor initialization process. 
 
Image Sensors may be enrolled in groups 15, 17, 20, or 25. The Image Sensors 
must follow the partition and group of the alarm hardwire and cannot be individually 
configured.   
 
After enrollment, be sure to keep the sensor and panel powered so the sensor can 
complete an initialization process with the Alarm.com Network Operations Center. 
This process will take several minutes. Images cannot be captured until initialization 
is complete. 

7.  Choose Sensor Location and Mount  

a.  Determine sensor mounting location

 based on installation scenario and criteria 

noted 

in the “Installation Guidelines.” For best image capture, the target capture 

areas should be centered in the frame. (e.g. If customer wants to capture people 
coming through door, the doorway should be centered in camera/PIR view.)

 

Blue Hardwire 