en
Startup
16
HWA 4000 / 4500 FCS
1. Open the filling screw
(Fig. A -3)
with the filter
key
(Fig. C -19/A)
.
2. Fill with water via the filling screw until the
pump housing
(Fig. A -2)
is full.
3. Screw the filling screw in.
Switching the pump on
1. Open one of the closing off devices (e.g. water
cock) in the pressure line.
2. Insert the mains plug on the connection cable
into the plug socket.
➯
The pumps starts to feed.
3. When no more air comes out with the water,
close the closing off device in the pressure
line.
➯
The pump switches off automatically af-
ter the switch-off pressure has been re-
ached. The house water system is ready
for operation.
➯
The LED displays are off.
➯
If water is being fed, just the LED display
PUMP ON lights up.
Initial commissioning
In the initial commissioning, the LED displays
PUMP ON and the LED display FLOW CONTROL
flashes.
ADVICE
If no water is being drawn up via the suc-
tion line after approx. 90 seconds, the dry
running protection system switches the
pump off and the LED display
ALARM
lights up. Check for leaks in the suction
line, the filter glass and all screwed fit-
tings, push the
RESET button
and re-
peat the initial commissioning process.
Switch the pump off
1. Remove the mains plug from the socket
2. Close one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10)
.
ADVICE
If no suction takes place within a period
of 180 seconds, the garden pump au-
tomatically goes to "fault" condition and
switches off.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
Check the air pressure in the storage vessel
CAUTION!
Check the air pressure in the storage
vessel at regular intervals. It must not ex-
ceed 1.5 bar (see Section "Commissio-
ning: Checking the Air Pressure in the
Storage Vessel").
Cleaning the pump
ADVICE
After conveying swimming pool water
containing chlorine or fluids that leave a
residue, the pump must be flushed out
with clear water.
1. Isolate the unit from the mains and secure
against switching on again.
➯
The pump stops automatically.
2. Flush the pump out with clear water.
3. Insert the mains plug into the plug socket.
4. Switch the house water system on with the
on /off switch
(Fig. A -6)
.
➯
The pump starts automatically.
Summary of Contents for HW 4000 FCS
Page 1: ...467 776_a I 05 2012 057 HW 4000 FCS HW 4500 FCS Betriebsanleitung...
Page 168: ...ru 168 HWA 4000 4500 FCS comfort 27 28 29 INOX INOX ADVICE 35 C ADVICE 15 20 90...
Page 172: ...ru 172 HWA 4000 4500 FCS comfort 3 1 2 3 4 5 6 ADVICE ADVICE 1 18 13 2 10 6 3 9 6 4 9 10...
Page 173: ...467 776_a 173 30 AL KO 1 5 ADVICE RESET...
Page 174: ...ru 174 HWA 4000 4500 FCS comfort RESET 90 RESET...
Page 175: ...467 776_a 175 xxx xxx x...
Page 178: ...uk 178 HWA 4000 4500 FCS comfort 29 INOX INOX ADVICE 35 C ADVICE 15 20 90...
Page 183: ...467 776_a 183 30 AL KO 1 5 ADVICE...
Page 184: ...uk 184 HWA 4000 4500 FCS comfort RESET 90...
Page 188: ......
Page 189: ...McGrp Ru McGrp Ru...