background image

User manual 

Akyga AK-CA-25

1.   Alarm temperature indicator

      

The alarm temperature is set via the SET key (6). After exceeding this temperature, the module will automatically 

          increase the fan speed.

2.   Alarm indicator

      

The indicator will light up when the alarm temperature is exceeded and will go off after cool down.

3.   Fan power indicator

      

Lights up when the fan is running

4.   HDD / SSD disk activity indicator

      

Shows the activity of a hard disk drive

5.   RESET button

      

Resets the alarm temperature and fan power to the basic settings.

6.   SET button

      

Gradually increases the alarm temperature.

7.   UP button

      

Gradually increases the fan power.

8.   Fan speed indicator

      

Indicates the current fan speed (a fan with a 3-pin plug is required for proper operation).

9.   Fan power indicator

      

Indicates the current fan power (gradually every 20%).

10. Temperature indicator

      

Indicates actual temperature.

11. 3-pin fan power connector

      

For fan power supply (necessary for proper operation)

12. Goldpin HDD / SSD plug

      

Optional (needed only for proper operation HDD / SSD disk activity indicator (4) )

13. Thermometer sensor

      

Place close to a place that is exposed to overheating (necessary for proper operation)

14. MOLEX connector 

      

Power the LCD panel and fan (necessary for proper operation)

NOTE: Panel during anomalies (eg no fan speed readout (8) or alarm temperature occurrence is beeping

Reviews: